["Laboratory Test, Performed": "HbA1c Laboratory Test"]

Performance/Reporting Period
2021
Value Set Description from VSAC
Clinical Focus: This value set contains concepts that represent hemoglobin A1c laboratory tests.
Data Element Scope: This value set may use the Quality Data Model (QDM) category related to Laboratory Test.
Inclusion Criteria: Includes only relevant concepts associated with identifying hemoglobin A1c laboratory tests.
Exclusion Criteria: Excludes codes that identify hemoglobin A1c laboratory tests that use the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) protocol and Japanese Diabetes Society (JDS)/Japanese Society of Clinical Chemistry (JSCC) protocol.

Constrained to codes in the Laboratory Test, Performed: HbA1c Laboratory Test value set (2.16.840.1.113883.3.464.1003.198.12.1013)

QDM Datatype and Definition (QDM Version 5.5 Guidance Update)

"Laboratory Test, Performed"

Data elements that meet criteria using this datatype should document the laboratory test indicated by the QDM category and its corresponding value set was performed.

A QDM Known Issue has been identified related to this datatype. To see this QDM known Issue, please click here.    

Timing:

  • relevant dateTime references the time the laboratory test is performed when the laboratory test occurs at a single point in time.
  • relevantPeriod references a start and stop time for a laboratory test that occurs over a time interval. relevantPeriod addresses:
    • startTime - The time the laboratory test begins.
    • stopTime - The time the laboratory test ends.
  • author dateTime references the time the action was recorded.
  • Refer to the eCQM expression to determine allowable timings to meet measure criterion.

Examples:

  • Initiation of a venipuncture for a fasting blood glucose to the time venipuncture for the fasting blood glucose is completed – use relevant dateTime to reference this single point in time for many specimen collections
  • Initiation of a 24-hour urine collection for measured creatinine clearance until completion of the 24-hour urine collection – use relevantPeriod to reference the start to stop time for this event.

Notes:

  • The time that the result report is available is a separate attribute than the time of the study (specimen collection).
  • negation rationale indicates a one-time documentation of a reason an activity is not performed. Negation of QDM datatype-related actions for a reason always use the author dateTime attribute to reference timing and must not use relevantPeriod.
QDM Attributes

relevantDateTime

Relevant dateTime addresses the time an activity occurs as a single point in time. If the activity occurs over a period of time, use Relevant Period.