Controlling High Blood Pressure
Compare Versions of: "Controlling High Blood Pressure"
The Compare function compares two years of the measure specifications found in the header of the measure's HTML. It does not include a comparison of any information in the body of the HTML, e.g., population criteria, Clinical Quality Language, or value sets.
Strikethrough text highlighted in red indicates information changed from the previous version. Text highlighted in green indicates information updated in the new eCQM version.
Compare version to
Measure Information | 2022 Performance Period | 2023 Performance Period | 2024 Performance Period | 2025 Performance Period |
---|---|---|---|---|
Title | Controlling High Blood Pressure | Controlling High Blood Pressure | Controlling High Blood Pressure | Controlling High Blood Pressure |
CMS eCQM ID | CMS165v10 | CMS165v11 | CMS165v12 | CMS165v13 |
CBE ID* | Not Applicable | Not Applicable | Not Applicable | Not Applicable |
MIPS Quality ID | 236 | 236 | 236 | 236 |
Measure Steward | National Committee for Quality Assurance | National Committee for Quality Assurance | National Committee for Quality Assurance | National Committee for Quality Assurance |
Description |
Percentage of patients 18-85 years of age who had a diagnosis of essential hypertension starting before and continuing into, or starting during the first six months of the measurement period, and whose most recent blood pressure was adequately controlled (<140/90mmHg) during the measurement period |
Percentage of patients 18-85 years of age who had a diagnosis of essential hypertension starting before and continuing into, or starting during the first six months of the measurement period, and whose most recent blood pressure was adequately controlled (<140/90mmHg) during the measurement period |
Percentage of patients 18-85 years of age who had a diagnosis of essential hypertension starting before and continuing into, or starting during the first six months of the measurement period, and whose most recent blood pressure was adequately controlled (<140/90 mmHg) during the measurement period |
Percentage of patients 18-85 years of age who had a diagnosis of essential hypertension starting before and continuing into, or starting during the first six months of the measurement period, and whose most recent blood pressure was adequately controlled (<140/90 mmHg) during the measurement period |
Measure Scoring | Proportion measure | Proportion measure | Proportion measure | Proportion measure |
Measure Type | Intermediate Clinical Outcome | Intermediate Clinical Outcome | Intermediate Clinical Outcome | Intermediate Clinical Outcome |
Stratification | *See CMS165v10.html | *See CMS165v11.html |
None |
None |
Risk Adjustment | *See CMS165v10.html | *See CMS165v11.html |
None |
None |
Rationale | *See CMS165v10.html | *See CMS165v11.html |
High blood pressure (HBP), also known as hypertension, is when the pressure in blood vessels is higher than normal (Centers for Disease Control and Prevention [CDC], 2021). The causes of hypertension are multiple and multifaceted and can be based on genetic predisposition, environmental risk factors, being overweight and obese, sodium intake, potassium intake, physical activity, and alcohol use. High blood pressure is common; according to the American Heart Association, between 2013-2016, approximately 121.5 million US adults >= 20 years of age had HBP and the prevalence of hypertension among US adults 65 and older was 77.0 percent (Virani et al., 2021). In an analysis of adults with hypertension in NHANES, the estimated age-adjusted proportion with controlled BP increased from 31.8 percent in 1999 to 53.8 percent in 2014. However, that proportion declined to 43.7 percent in 2017 to 2018 (Tsao et al., 2022). HBP, known as the “silent killer,” increases risks of heart disease and stroke which are two of the leading causes of death in the US; a person who has HBP is four times more likely to die from a stroke and three times more likely to die from heart disease (CDC, 2012). The National Center for Health Statistics reported that in 2020 there were over 670,000 deaths with HBP as a primary or contributing cause (CDC, 2022). Between 2009 and 2019 the number of deaths due to HBP rose by 65.3 percent (Tsao et al., 2022). Managing and treating HBP would reduce cardiovascular disease mortality for males and females by 30.4 percent and 38.0 percent, respectively (Patel et al., 2015). Age-adjusted death rates attributable to HBP in 2019 were more than twice as high in non-Hispanic Black males (56.7 percent) when compared to rates for non-Hispanic White males (25.7 percent) (Tsao et al., 2022). HBP costs the U.S. approximately 131 billion dollars each year, averaged over 12 years from 2003 to 2014 (Kirkland et al., 2018). A study on cost-effectiveness on treating hypertension found that controlling HBP in patients with cardiovascular disease and systolic blood pressures (SBP) of >= 160 mmHg could be effective and cost-saving (Moran, 2015). Many studies have shown that controlling high blood pressure reduces cardiovascular events and mortality. The Systolic Blood Pressure Intervention Trial (SPRINT) investigated the impact of obtaining a SBP goal of <120 mmHg compared to a SBP goal of <140 mmHg among patients 50 and older with established cardiovascular disease and found that the patients with the former goal had reduced cardiovascular events and mortality (SPRINT Research Group et al., 2015). Controlling HBP will significantly reduce the risks of cardiovascular disease mortality and lead to better health outcomes like reduction of heart attacks, stroke, and kidney disease (James et al., 2014). Thus, the relationship between the measure (control of hypertension) and the long-term clinical outcomes listed is well established. |
High blood pressure (HBP), also known as hypertension, is when the pressure in blood vessels is higher than normal (Centers for Disease Control and Prevention [CDC], 2023). The causes of hypertension are multiple and multifaceted and can be based on genetic predisposition, environmental risk factors, being overweight and obese, sodium intake, potassium intake, physical activity, and alcohol use. High blood pressure is common; according to the American Heart Association, between 2013-2016, approximately 121.5 million US adults >= 20 years of age had HBP and the prevalence of hypertension among US adults 65 and older was 77.0 percent (Virani et al., 2021). In an analysis of adults with hypertension in National Health and Nutrition Examination Survey (NHANES), the estimated age-adjusted proportion with controlled blood pressure (BP) increased from 31.8 percent in 1999 to 53.8 percent in 2014. However, that proportion declined to 43.7 percent in 2017 to 2018 (Tsao et al., 2022). HBP increases risks of heart disease and stroke which are two of the leading causes of death in the US (CDC, 2023). A person who has HBP is four times more likely to die from a stroke and three times more likely to die from heart disease (CDC, 2021). The National Center for Health Statistics reported that in 2020 there were over 670,000 deaths with HBP as a primary or contributing cause (CDC, 2022). Between 2009 and 2019 the number of deaths due to HBP rose by 65.3 percent (Tsao et al., 2022). Managing and treating HBP would reduce cardiovascular disease mortality for males and females by 30.4 percent and 38.0 percent, respectively (Patel et al., 2015). Age-adjusted death rates attributable to HBP in 2019 were more than twice as high in non-Hispanic Black males (56.7 percent) when compared to rates for non-Hispanic White males (25.7 percent) (Tsao et al., 2022). HBP costs the U.S. approximately 131 billion dollars each year, averaged over 12 years from 2003 to 2014 (Kirkland et al., 2018). A study on cost-effectiveness on treating hypertension found that controlling HBP in patients with cardiovascular disease and systolic blood pressures (SBP) of >= 160 mmHg could be effective and cost-saving (Moran et al., 2015). Many studies have shown that controlling high blood pressure reduces cardiovascular events and mortality. The Systolic Blood Pressure Intervention Trial (SPRINT) investigated the impact of obtaining a SBP goal of <120 mmHg compared to a SBP goal of <140 mmHg among patients 50 and older with established cardiovascular disease and found that the patients with the former goal had reduced cardiovascular events and mortality (SPRINT Research Group et al., 2015). Controlling HBP will significantly reduce the risks of cardiovascular disease mortality and lead to better health outcomes like reduction of heart attacks, stroke, and kidney disease (James et al., 2014). Thus, the relationship between the measure (control of hypertension) and the long-term clinical outcomes listed is well established. |
Clinical Recommendation Statement | *See CMS165v10.html | *See CMS165v11.html |
U.S. Preventive Services Task Force (USPSTF) (2021): - The USPSTF recommends screening for hypertension in adults 18 years or older with office blood pressure measurement (OBPM). The USPSTF recommends obtaining blood pressure measurements outside of the clinical setting for diagnostic confirmation before starting treatment. This is a grade A recommendation. American College of Cardiology/American Heart Association (2017): - For adults with confirmed hypertension and known CVD or 10-year ASCVD event risk of 10 percent or higher, a blood pressure target of less than 130/80 mmHg is recommended (Level of evidence: B-R (for systolic blood pressures), Level of evidence: C-EO (for diastolic blood pressure)) - For adults with confirmed hypertension, without additional markers of increased CVD risk, a blood pressure target of less than 130/80 mmHg may be reasonable (Note: clinical trial evidence is strongest for a target blood pressure of 140/90 mmHg in this population. However, observational studies suggest that these individuals often have a high lifetime risk and would benefit from blood pressure control earlier in life) (Level of evidence: B-NR (for systolic blood pressure), Level of evidence: C-EO (for diastolic blood pressure)). American College of Physicians and the American Academy of Family Physicians (2017): - Initiate or intensify pharmacologic treatment in some adults aged 60 years or older at high cardiovascular risk, based on individualized assessment, to achieve a target systolic blood pressure of less than 140 mmHg (Grade: weak recommendation, Quality of evidence: low) - Initiate or intensify pharmacologic treatment in adults aged 60 years or older with a history of stroke or transient ischemic attack to achieve a target systolic blood pressure of less than 140 mmHg to reduce the risk of recurrent stroke (Grade: weak recommendation, Quality of evidence: moderate) American Diabetes Association (2021): - For individuals with diabetes and hypertension at higher cardiovascular risk (existing atherosclerotic cardiovascular disease or 10-year atherosclerotic cardiovascular disease risk >=15 percent), a blood pressure target of <130/80 mmHg may be appropriate, if it can be safely attained (Level of evidence: C) - For individuals with diabetes and hypertension at lower risk for cardiovascular disease (10-year atherosclerotic cardiovascular disease risk <15 percent), treat to a blood pressure target of <140/90 mmHg (Level of evidence: A) |
U.S. Preventive Services Task Force (USPSTF) (2021): - The USPSTF recommends screening for hypertension in adults 18 years or older with office blood pressure measurement (OBPM). The USPSTF recommends obtaining blood pressure measurements outside of the clinical setting for diagnostic confirmation before starting treatment. This is a grade A recommendation. American College of Cardiology/American Heart Association (2017): - For adults with confirmed hypertension and known cardiovascular disease (CVD) or 10-year atherosclerotic cardiovascular disease (ASCVD) event risk of 10 percent or higher, a blood pressure target of less than 130/80 mmHg is recommended (Level of evidence: B-R (for systolic blood pressures), Level of evidence: C-EO (for diastolic blood pressure)) - For adults with confirmed hypertension, without additional markers of increased CVD risk, a blood pressure target of less than 130/80 mmHg may be reasonable (Note: clinical trial evidence is strongest for a target blood pressure of 140/90 mmHg in this population. However, observational studies suggest that these individuals often have a high lifetime risk and would benefit from blood pressure control earlier in life) (Level of evidence: B-NR (for systolic blood pressure), Level of evidence: C-EO (for diastolic blood pressure)). American Academy of Family Physicians (2022): - Treat adults who have hypertension to a standard blood pressure target (less than 140/90 mm Hg) to reduce the risk of all-cause and cardiovascular mortality (strong recommendation; high-quality evidence). Treating to a lower blood pressure target (less than 135/85 mm Hg) does not provide additional benefit at preventing mortality; however, a lower blood pressure target could be considered based on patient preferences and values. (Grade: strong recommendation, Quality of evidence: high) - Consider treating adults who have hypertension to a lower blood pressure target (less than 135/85 mm Hg) to reduce risk of myocardial infarction (weak recommendation; moderate-quality evidence). Although treatment to a standard blood pressure target (less than 140/90 mm Hg) reduced the risk of myocardial infarction, there was a small additional benefit observed with a lower blood pressure target. There was no observed additional benefit in preventing stroke with the lower blood pressure target. (Grade: weak recommendation, Quality of evidence: low) American Diabetes Association (2022): - For individuals with diabetes and hypertension at higher cardiovascular risk (existing atherosclerotic cardiovascular disease or 10-year atherosclerotic cardiovascular disease risk >=15 percent), a blood pressure target of <130/80 mmHg may be appropriate, if it can be safely attained (Level of evidence: B) - For individuals with diabetes and hypertension at lower risk for cardiovascular disease (10-year atherosclerotic cardiovascular disease risk <15 percent), treat to a blood pressure target of <140/90 mmHg (Level of evidence: A) |
Improvement Notation |
Higher score indicates better quality |
Higher score indicates better quality |
Higher score indicates better quality |
Higher score indicates better quality |
Definition | *See CMS165v10.html | *See CMS165v11.html |
None |
None |
Guidance |
In reference to the numerator element, only blood pressure readings performed by a clinician or a remote monitoring device are acceptable for numerator compliance with this measure. This includes blood pressures taken in person by a clinician and blood pressures measured remotely by electronic monitoring devices capable of transmitting the blood pressure data to the clinician. Blood pressure readings taken by a remote monitoring device and conveyed by the patient to the clinician are also acceptable. It is the clinician’s responsibility and discretion to confirm the remote monitoring device used to obtain the blood pressure is considered acceptable and reliable and whether the blood pressure reading is considered accurate before documenting it in the patient’s medical record. Do not include BP readings: -Taken during an acute inpatient stay or an ED visit -Taken on the same day as a diagnostic test or diagnostic or therapeutic procedure that requires a change in diet or change in medication on or one day before the day of the test or procedure, with the exception of fasting blood tests. -Taken by the patient using a non-digital device such as with a manual blood pressure cuff and a stethoscope. If no blood pressure is recorded during the measurement period, the patient's blood pressure is assumed "not controlled." If there are multiple blood pressure readings on the same day, use the lowest systolic and the lowest diastolic reading as the most recent blood pressure reading. This eCQM is a patient-based measure. This version of the eCQM uses QDM version 5.5. Please refer to the eCQI resource center for more information on the QDM. |
In reference to the numerator element, only blood pressure readings performed by a clinician or a remote monitoring device are acceptable for numerator compliance with this measure. This includes blood pressures taken in person by a clinician and blood pressures measured remotely by electronic monitoring devices capable of transmitting the blood pressure data to the clinician. Blood pressure readings taken by a remote monitoring device and conveyed by the patient to the clinician are also acceptable. It is the clinician’s responsibility and discretion to confirm the remote monitoring device used to obtain the blood pressure is considered acceptable and reliable and whether the blood pressure reading is considered accurate before documenting it in the patient’s medical record. Do not include BP readings taken during an acute inpatient stay or an ED visit. If no blood pressure is recorded during the measurement period, the patient's blood pressure is assumed "not controlled". If there are multiple blood pressure readings on the same day, use the lowest systolic and the lowest diastolic reading as the most recent blood pressure reading. Ranges and thresholds do not meet criteria for this measure. A distinct numeric result for both the systolic and diastolic BP reading is required for numerator compliance. This eCQM is a patient-based measure. This version of the eCQM uses QDM version 5.6. Please refer to the QDM page for more information on the QDM. |
In reference to the numerator element, only blood pressure readings performed by a clinician or an automated blood pressure monitor or device are acceptable for numerator compliance with this measure. This includes blood pressures taken in person by a clinician and blood pressures measured remotely by electronic monitoring devices capable of transmitting the blood pressure data to the clinician. Blood pressure readings taken by an automated blood pressure monitor or device and conveyed by the patient to the clinician are also acceptable. It is the clinician’s responsibility and discretion to confirm the automated blood pressure monitor or device used to obtain the blood pressure is considered acceptable and reliable and whether the blood pressure reading is considered accurate before documenting it in the patient’s medical record. Do not include BP readings taken during an acute inpatient stay or an ED visit. If no blood pressure is recorded during the measurement period, the patient's blood pressure is assumed "not controlled". If there are multiple blood pressure readings on the same day, use the lowest systolic and the lowest diastolic reading as the most recent blood pressure reading. Ranges and thresholds do not meet criteria for this measure. A distinct numeric result for both the systolic and diastolic BP reading is required for numerator compliance. This eCQM is a patient-based measure. This version of the eCQM uses QDM version 5.6. Please refer to the QDM page for more information on the QDM. |
In reference to the numerator element, only blood pressure readings performed by a clinician or an automated blood pressure monitor or device are acceptable for numerator compliance with this measure. This includes blood pressures taken in person by a clinician and blood pressures measured remotely by electronic monitoring devices capable of transmitting the blood pressure data to the clinician. Blood pressure readings taken by an automated blood pressure monitor or device and conveyed by the patient to the clinician are also acceptable. It is the clinician’s responsibility and discretion to confirm the automated blood pressure monitor or device used to obtain the blood pressure is considered acceptable and reliable and whether the blood pressure reading is considered accurate before documenting it in the patient’s medical record. Do not include BP readings taken during an acute inpatient stay or an emergency department (ED) visit. If no blood pressure is recorded during the measurement period, the patient's blood pressure is assumed "not controlled". If there are multiple blood pressure readings on the same day, use the lowest systolic and the lowest diastolic reading as the most recent blood pressure reading. Ranges and thresholds do not meet criteria for this measure. A distinct numeric result for both the systolic and diastolic BP reading is required for numerator compliance. This eCQM is a patient-based measure. This version of the eCQM uses QDM version 5.6. Please refer to the QDM page for more information on the QDM. |
Initial Population |
Patients 18-85 years of age who had a visit and diagnosis of essential hypertension starting before and continuing into, or starting during the first six months of the measurement period. |
Patients 18-85 years of age by the end of the measurement period who had a visit and diagnosis of essential hypertension starting before and continuing into, or starting during the first six months of the measurement period |
Patients 18-85 years of age by the end of the measurement period who had a visit during the measurement period and diagnosis of essential hypertension starting before and continuing into, or starting during the first six months of the measurement period |
Patients 18-85 years of age by the end of the measurement period who had a visit during the measurement period and diagnosis of essential hypertension starting before and continuing into, or starting during the first six months of the measurement period |
Denominator |
Equals Initial Population |
Equals Initial Population |
Equals Initial Population |
Equals Initial Population |
Denominator Exclusions |
Patients with evidence of end stage renal disease (ESRD), dialysis or renal transplant before or during the measurement period. Also exclude patients with a diagnosis of pregnancy during the measurement period. Exclude patients who are in hospice care for any part of the measurement period. Exclude patients 66 and older who are living long term in an institution for more than 90 consecutive days during the measurement period. Exclude patients 66 and older with an indication of frailty for any part of the measurement period who meet any of the following criteria: - Advanced illness with two outpatient encounters during the measurement period or the year prior - OR advanced illness with one inpatient encounter during the measurement period or the year prior - OR taking dementia medications during the measurement period or the year prior Exclude patients 81 and older with an indication of frailty for any part of the measurement period. Exclude patients receiving palliative care during the measurement period. |
Patients with evidence of end stage renal disease (ESRD), dialysis or renal transplant before or during the measurement period. Also exclude patients with a diagnosis of pregnancy during the measurement period. Exclude patients who are in hospice care for any part of the measurement period. Exclude patients 66 and older by the end of the measurement period who are living long term in a nursing home any time on or before the end of the measurement period. Exclude patients 66-80 by the end of the measurement period with an indication of frailty for any part of the measurement period who also meet any of the following advanced illness criteria: - Advanced illness with two outpatient encounters during the measurement period or the year prior - OR advanced illness with one inpatient encounter during the measurement period or the year prior - OR taking dementia medications during the measurement period or the year prior Exclude patients 81 and older by the end of the measurement period with an indication of frailty for any part of the measurement period. Exclude patients receiving palliative care for any part of the measurement period. |
Patients with evidence of end stage renal disease (ESRD), dialysis or renal transplant before or during the measurement period. Also exclude patients with a diagnosis of pregnancy during the measurement period. Exclude patients who are in hospice care for any part of the measurement period. Exclude patients 66 and older by the end of the measurement period who are living long term in a nursing home any time on or before the end of the measurement period. Exclude patients 66-80 by the end of the measurement period with an indication of frailty for any part of the measurement period who also meet any of the following advanced illness criteria: - Advanced illness with two outpatient encounters during the measurement period or the year prior - OR advanced illness with one inpatient encounter during the measurement period or the year prior - OR taking dementia medications during the measurement period or the year prior Exclude patients 81 and older by the end of the measurement period with an indication of frailty for any part of the measurement period. Exclude patients receiving palliative care for any part of the measurement period. |
Exclude patients who are in hospice care for any part of the measurement period. Patients with evidence of end stage renal disease (ESRD), dialysis or renal transplant before or during the measurement period. Also exclude patients with a diagnosis of pregnancy during the measurement period. Exclude patients 66-80 by the end of the measurement period with an indication of frailty for any part of the measurement period who also meet any of the following advanced illness criteria: - Advanced illness diagnosis during the measurement period or the year prior - OR taking dementia medications during the measurement period or the year prior Exclude patients 81 and older by the end of the measurement period with an indication of frailty for any part of the measurement period. Exclude patients 66 and older by the end of the measurement period who are living long term in a nursing home any time on or before the end of the measurement period. Exclude patients receiving palliative care for any part of the measurement period. |
Numerator |
Patients whose most recent blood pressure is adequately controlled (systolic blood pressure < 140 mmHg and diastolic blood pressure < 90 mmHg) during the measurement period |
Patients whose most recent blood pressure is adequately controlled (systolic blood pressure < 140 mmHg and diastolic blood pressure < 90 mmHg) during the measurement period |
Patients whose most recent blood pressure is adequately controlled (systolic blood pressure < 140 mmHg and diastolic blood pressure < 90 mmHg) during the measurement period |
Patients whose most recent blood pressure is adequately controlled (systolic blood pressure < 140 mmHg and diastolic blood pressure < 90 mmHg) during the measurement period |
Numerator Exclusions |
Not Applicable |
Not Applicable |
Not Applicable |
Not Applicable |
Denominator Exceptions |
None |
None |
None |
None |
Telehealth Eligible | Yes | Yes | Yes | Yes |
Next Version | No Version Available | |||
Previous Version | No Version Available |
Additional Resources for CMS165v10
Header
Updated the eCQM version number.
Measure Section: eCQM Version Number
Source of Change: Annual Update
Updated the measure description to align with the measure intent and guidance.
Measure Section: Description
Source of Change: Measure Lead
Updated copyright.
Measure Section: Copyright
Source of Change: Annual Update
Updated the rationale to align with current evidence.
Measure Section: Rationale
Source of Change: Measure Lead
Updated references.
Measure Section: Reference
Source of Change: Annual Update
Revised the guidance language to further clarify the measure intent.
Measure Section: Guidance
Source of Change: Measure Lead
Updated the Denominator Exclusions to add an exclusion for palliative care.
Measure Section: Denominator Exclusions
Source of Change: Measure Lead
Revised the advanced illness and frailty denominator exclusion to clarify the intent of the exclusion criteria.
Measure Section: Denominator Exclusions
Source of Change: Measure Lead
Replaced 'overlaps' or 'overlapping' in the denominator exclusions with plain language to clarify the measure intent.
Measure Section: Denominator Exclusions
Source of Change: Measure Lead
Revised the timing associated with the essential hypertension diagnosis within the narrative to align with the measure intent.
Measure Section: Multiple Sections
Source of Change: Measure Lead
Logic
Added online assessments and telephone visits as appropriate encounters based on the increased use of telehealth services.
Measure Section: Initial Population
Source of Change: Measure Lead
Removed comments from the 'Qualifying Diastolic Blood Pressure Reading' and 'Qualifying Systolic Blood Pressure Reading'definitions to streamline the logic.
Measure Section: Definitions
Source of Change: Measure Lead
Updated the names of Clinical Quality Language (CQL) definitions, functions, and/or aliases for clarification and to align with the CQL Style Guide.
Measure Section: Multiple Sections
Source of Change: Standards Update
Updated the version number of the Measure Authoring Tool (MAT) Global Common Functions Library (MATGlobalCommonFunctions-6.2.000). Updated the 'Inpatient Encounter' definition to include a 'day of' timing clarification. Added the following timing functions: Normalize Interval, Has Start, Has End, Latest, Latest Of, Earliest, and Earliest Of. Please see individual measure details for application of specific timing functions.
Measure Section: Multiple Sections
Source of Change: Standards Update
Updated Denominator Exclusions definition and added PalliativeCare.Palliative Care in the Measurement Period definition to add an exclusion for palliative care.
Measure Section: Multiple Sections
Source of Change: Measure Lead
Revised the advanced illness and frailty denominator exclusion to align with the header and adhere to QDMv5.5 standards.
Measure Section: Multiple Sections
Source of Change: Measure Lead
Removed the Vascular Access for Dialysis value set from the Renal Procedures definition to streamline existing value sets and reduce redundancies.
Measure Section: Multiple Sections
Source of Change: Measure Lead
Revised the timing associated with the essential hypertension diagnosis in the Essential Hypertension Diagnosis definition to align with the measure intent.
Measure Section: Multiple Sections
Source of Change: Measure Lead
Added new NormalizeInterval function to timing attributes to decrease implementation burden due to variable use of timing attributes for select QDM data types. The NormalizeInterval function was applied, where applicable, for the following data elements: Assessment, Performed; Device, Applied; Diagnostic Study, Performed; Intervention, Performed; Laboratory Test, Performed; Medication, Administered; Medication, Dispensed; Physical Exam, Performed; Procedure, Performed; Substance, Administered.
Measure Section: Multiple Sections
Source of Change: Standards Update
Revised the timing of the ESRD encounter in the End Stage Renal Disease Encounter definition to align with the measure intent and to capture encounters on the last day of the measurement period.
Measure Section: Multiple Sections
Source of Change: Measure Lead
Update Adult Outpatient Encounters CQL library to 2.0.000.
Measure Section: Multiple Sections
Source of Change: Measure Lead
Updated Advanced Illness and Frailty Exclusions CQL Library to version 6.0.000.
Measure Section: Multiple Sections
Source of Change: Measure Lead
Updated Hospice CQL Library to version 3.0.000.
Measure Section: Multiple Sections
Source of Change: Measure Lead
Added PalliativeCareExclusion CQL library version 1.0.000.
Measure Section: Multiple Sections
Source of Change: Measure Lead
Value Set
The VSAC is the source of truth for the value set content, please visit the VSAC for downloads of current value sets.
Removed value set Vascular Access for Dialysis (2.16.840.1.113883.3.464.1003.109.12.1011) based on change in measure requirements/measure specification.
Measure Section: Terminology
Source of Change: Measure Lead
Value set Pregnancy (2.16.840.1.113883.3.526.3.378): Added 77 ICD-10-CM codes based on review by technical experts, SMEs, and/or public feedback. Deleted 19 ICD-10-CM codes based on review by technical experts, SMEs, and/or public feedback. Deleted 24 SNOMED CT codes based on review by technical experts, SMEs, and/or public feedback.
Measure Section: Terminology
Source of Change: Measure Lead
Value set Dialysis Services (2.16.840.1.113883.3.464.1003.109.12.1013): Added 3 CPT codes (99512, 90997, 90999) based on updated evidence in published guidelines, published literature, or from published specialty medical society or group recommendations. Deleted 5 CPT codes (1019320, 90940, 90957, 90958, 90959) based on updated evidence in published guidelines, published literature, or from published specialty medical society or group recommendations. Added 1 HCPCS code (S9339) based on updated evidence in published guidelines, published literature, or from published specialty medical society or group recommendations.
Measure Section: Terminology
Source of Change: Measure Lead
Value set Essential Hypertension (2.16.840.1.113883.3.464.1003.104.12.1011): Added 2 SNOMED CT codes (1078301000112109, 461301000124109) based on updated evidence in published guidelines, published literature, or from published specialty medical society or group recommendations.
Measure Section: Terminology
Source of Change: Measure Lead
Value set Kidney Transplant (2.16.840.1.113883.3.464.1003.109.12.1012): Added 13 SNOMED CT codes based on review by technical experts, SMEs, and/or public feedback. Deleted 35 SNOMED CT codes based on review by technical experts, SMEs, and/or public feedback. Deleted 4 CPT codes (50300, 50320, 50340, 50370) based on review by technical experts, SMEs, and/or public feedback.
Measure Section: Terminology
Source of Change: Measure Lead
Value set Advanced Illness (2.16.840.1.113883.3.464.1003.110.12.1082): Added 34 ICD-10-CM codes based on updated evidence in published guidelines, published literature, or from published specialty medical society or group recommendations or terminology updates. Added 179 SNOMED CT codes based on updated evidence in published guidelines, published literature, or from published specialty medical society or group recommendations, and based on terminology updates.
Measure Section: Terminology
Source of Change: Measure Lead
Value set Outpatient (2.16.840.1.113883.3.464.1003.101.12.1087): Added 11 SNOMED CT codes (185463005, 185464004, 185465003, 281036007, 30346009, 37894004, 3391000175108, 439740005, 77406008, 444971000124105, 84251009) based on review by technical experts, SMEs, and/or public feedback.
Measure Section: Terminology
Source of Change: Measure Lead
Value set Frailty Device (2.16.840.1.113883.3.464.1003.118.12.1300): Added 124 SNOMED CT codes based on review by technical experts, SMEs, and/or public feedback. Deleted 22 SNOMED CT codes based on review by technical experts, SMEs, and/or public feedback.
Measure Section: Terminology
Source of Change: Measure Lead
Value set Frailty Encounter (2.16.840.1.113883.3.464.1003.101.12.1088): Deleted 1 SNOMED CT code (413467001) based on review by technical experts, SMEs, and/or public feedback.
Measure Section: Terminology
Source of Change: Measure Lead
Value set Frailty Symptom (2.16.840.1.113883.3.464.1003.113.12.1075): Added 13 SNOMED CT codes based on review by technical experts, SMEs, and/or public feedback. Deleted 69 SNOMED CT codes based on review by technical experts, SMEs, and/or public feedback.
Measure Section: Terminology
Source of Change: Measure Lead
Value set Frailty Diagnosis (2.16.840.1.113883.3.464.1003.113.12.1074): Added 14 SNOMED CT codes based on review by technical experts, SMEs, and/or public feedback. Deleted 13 SNOMED CT codes based on review by technical experts, SMEs, and/or public feedback. Added 166 ICD-10-CM codes based on review by technical experts, SMEs, and/or public feedback.
Measure Section: Terminology
Source of Change: Measure Lead
Value set Dementia Medications (2.16.840.1.113883.3.464.1003.196.12.1510): Added 4 RxNorm codes (1599803, 1599805, 1805420, 1805425) based on change in measure requirements/measure specification. Deleted 3 RxNorm codes (1858970, 996572, 996624) based on change in measure requirements/measure specification.
Measure Section: Terminology
Source of Change: Measure Lead
Value set Acute Inpatient (2.16.840.1.113883.3.464.1003.101.12.1083): Added 10 SNOMED CT codes (10378005, 18083007, 183452005, 19951005, 2252009, 73607007, 305339001, 50699000, 74857009, 78680009) based on updated evidence in published guidelines, published literature, or from published specialty medical society or group recommendations.
Measure Section: Terminology
Source of Change: Measure Lead
Added value set Palliative Care Encounter (2.16.840.1.113883.3.464.1003.101.12.1090) based on change in measure requirements/measure specification.
Measure Section: Terminology
Source of Change: Measure Lead
Added value set Palliative Care Intervention (2.16.840.1.113883.3.464.1003.198.12.1135) based on change in measure requirements/measure specification.
Measure Section: Terminology
Source of Change: Measure Lead
Added value set Telephone Visits (2.16.840.1.113883.3.464.1003.101.12.1080) based on change in measure requirements/measure specification.
Measure Section: Terminology
Source of Change: Measure Lead
Added value set Online Assessment (2.16.840.1.113883.3.464.1003.101.12.1089) based on change in measure requirements/measure specification.
Measure Section: Terminology
Source of Change: Measure Lead
Replaced value set ED (2.16.840.1.113883.3.464.1003.101.12.1085) with value set Emergency Department Visit (2.16.840.1.113883.3.464.1003.101.12.1010) based on review by technical experts, SMEs, and/or public feedback.
Measure Section: Terminology
Source of Change: Measure Lead
Added direct reference code LOINC code (71007-9) based on change in measure requirements/measure specification.
Measure Section: Terminology
Source of Change: Measure Lead