Back to top
Top
U.S. flag

An official website of the United States government

Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Value Set Information

Value sets are a subset of concepts (each concept represented by a code) drawn from one or more code systems, where the concepts included in the subset share a common scope of use. The codes and corresponding terms come from standard clinical vocabularies (such as Current Procedural Terminology [CPT], SNOMED CT, RxNorm, and Logical Observation Identifiers Names and Codes [LOINC]) and define clinical concepts to support effective and interoperable health information exchange. Value set authors use value sets in quality measures and clinical decision support to collect all the coded concepts that can occur in the clinical record (or administrative data), represent patients or encounters that should be in the same population for analysis, and provide condition-specific diagnostic support and order sets.

Value sets have a life cycle similar to many persistent objects. The Value Set Authority Center (VSAC) is a tool suite developed by the National Library of Medicine to support the creation, maintenance, and retrieval of value sets. The VSAC serves as the central repository for the CMS electronic clinical quality measure value sets. However, other value set repositories are available, such as the Public Health Information Vocabulary Access and Distribution System

The VSAC Support Center provides online information about VSAC access, value set lifecycles and workflow, measure developer and steward roles, and best practices for value set development. In addition, the VSAC Support Center offers archived users’ forums and release notes and provides links to VSAC publications.

Coded Data Elements

Coded data elements in quality measures are bound to (i.e., may use) either

  • A single specific code (drawn from a code system) directly referenced within the measure and, as such, is not a value set; therefore, it is a direct reference code (DRC).

OR

  • A value set (i.e., a set of codes) where each code is equivalent with respect to use in the context of that data element.

In quality measures, the patients or encounters identified using any of the codes in a value set are equivalent with respect to the measure data element using the value set.

Value Set Creation Methods

In VSAC, a value set contains specific codes derived from a single code system or vocabulary. Value set users refer to codes and their descriptions as concepts in VSAC, value set authors can group value sets to combine code systems. Value set authors can create value sets using several methods:

Extensional:

A set of concept codes and descriptors in the form of an enumerated list. An extensional value set in the VSAC contains codes from only one code system.

Intensional:

A list of codes based on a logical statement that often has an algorithmic basis for the selection of concepts based on concept properties or relationships as defined within the code system. An intensional value set in the VSAC contains codes from only one code system.

Grouping:

A collection of one or more value sets that, when combined, meet the requirements of the grouping value set purpose. Value set authors often use grouping value sets in the VSAC to combine member value sets from different code systems so the grouping value set expansion set includes concepts from multiple code systems. In VSAC, grouping value sets cannot group other grouping value sets.

Value set authors should create value sets with the thoughtful input of subject matter experts familiar with the clinical or administrative information needed, combined with the input of terminology experts familiar with the code systems used. This work requires strong knowledge of current information capture (both electronic encoding and traditional textual material) and the workflow necessary to capture the expected information accurately.

Representing the Codes for Inclusion

When constructing a value set, the value set author is actually constructing a value set definition (VSD) that may have multiple versions over time. A VSD describes the value set using metadata and includes a Content Logical Definition (CLD) that identifies the specific concepts (i.e., codes) for inclusion in the value set expansion. An expansion profile is a set of rules defined by a particular program, for example, the “eCQM Update 2022-05-05” expansion profile applied a set of allowable code system versions, defined by CMS. An additional rule in the expansion profile determines if the expansion will include concepts specified in the CLD that are inactive in the code system version used for the expansion.  In the Value Set Authority Center (VSAC), a download of the value set expansion will include the concept code, text display (description), the code system name, identifier, and the code system version used for each member in the expansion set.

Many constructed VSDs enumerate each desired specific code, traditionally called an enumerated or extensional definition. However, the best definition of many value sets is logically or intensionally using the structure of the specific code system (e.g., all the codes that are descendants of the condition Insulin Dependent Diabetes Mellitus). For example, "include all concepts that are children of a parent concept" in a hierarchical code system.

A simple enumeration of concepts is not always an ideal approach to define a value set. A comprehensive approach to quality measure development entails examination of complete code hierarchies in a code system to determine the levels of concept inclusion. The VSAC provides tooling to support both extensional and intensional VSDs.

Value Set Versioning

The value set author creates the value set definition to specify the value set content. The value set steward reviews and passes the value set definition and then publishes the value set definition. VSAC gives it a version identifier, known as “the value set definition version.”

A value set definition version update occurs whenever the steward publishes a new version. Possible reasons for a new version are when there is a change in the value set’s defined codes, grouping member value sets, or algorithmic logic (intensional).

When there is an expansion of a published value set definition, the result is a “value set expansion version.” The VSAC always makes available for use by value set users an expansion based on the current published value set definition version. That expansion version has the string identifier of “Latest” and the expansion content in Latest will change if the current value set definition changes to a new version and/or the code system version changes in a way to affect the constituent concepts.

Including Historical Codes

Some value sets may need to include concepts that are no longer active concepts in the code system of choice. This usually occurs when a measure clause includes a value set that requires a look-back period that extends back more than a year or the length of time between code system updates, due to the fact that the entry of the newly retired codes into patient records occurred when they were still active codes. No value set author should expect owners of old patient records will update content to use current codes. Therefore, value sets for use to identify patients based on old record content may need to include inactive legacy codes in the value set expansions. Value set authors should document the need for including retired codes in the purpose statements of the value set metadata section. Value set authors that need historical codes in an expansion must include those codes withing the CLD of the value set and confirm that the expansion profile used for the specified eCQM program release, sets the "Legacy/Retired Codes" rule to apply the most recent code system version that includes the code in an active status. 

This guidance is intended for value set authors. The guidance provides direction on the best practices for authoring and maintaining value sets for quality measures, electronic clinical quality improvement, and other applications.

CMS requires their contracted measure developers to follow this guidance unless otherwise stated in the contract or by their Contracting Officer’s Representative. CMS and other Health and Human Services agencies recommend other measure developers and authors of value sets follow these guidelines and principles for value set development and maintenance.

This value set guidance provides best practices in value set naming, descriptions, and maintenance.

Value Set Naming
Value Set NameGuidance
Limit the value set name to as few words as possible and no more than 128 characters.
  • Create a short, descriptive, user-friendly title for the value set.
  • Avoid a long description yet capture critical, distinctive aspects of the membership criteria.
Create the value set name to convey the specific distinguishing characteristics of the member concepts.
  • Use a sufficiently descriptive name.
    • The value set name "Diabetes" is not sufficiently descriptive if it only contains codes describing Type II diabetes.
    • The value set name "Diabetes Type II" is a better name because it more effectively describes the scope of the value set.
  • Avoid including descriptions of the intended, but not achieved, content.
Make value set names unique.
  • Use a sufficiently descriptive name.
  • Best practice discourages use of duplicate value set names and should be uncommon.
  • Grouping value sets may have member value sets with the same name, as these members often have the same purpose, yet their content is differentiated by specific code system content.
  • Value sets with different metadata (purpose, intent, inclusion, and exclusion statements) should always have names reflective of the metadata and therefore should have a unique name.
Use correct spelling and grammar.
  • Separate multi-word terms by spaces and not by any other characters.
  • Use title case (capitalize first letters of all words, except prepositions, as in a title).
  • Do not include "camelCase," composite, or delimited words or phrases.
Avoid these items in a value set name
  • The Value Set Authority Center (VSAC) prohibits certain characters (+ * ? : -| ! " %) and provides a system warning if used.
  • Value set steward name – The VSAC database captures the steward’s name in a separate field in the metadata, which is bound to the value set.
  • Name of the specific data element the value set was created to support.
    • Do not include the concept category that characterizes the context of use, unless it describes a primary distinguishing characteristic of the value set requirements.
    • For example, only include the word “Procedure” when the context of the focus is ambiguous.
      • Appropriate Name – Insulin Dependent Diabetes Diagnoses
      • Inappropriate Name – Diabetes Condition, Diagnosis, or Health Concern
      • Appropriate Name – Mobility-Related Health Concerns
      • Inappropriate Name – Mobility Health Concerns
    • Quality reporting program name unless it describes a primary distinguishing characteristic of the value set.
    • Names of measure types or settings (e.g., hospital measures, process measures).
    • Code descriptors within the value set name.
    • Abbreviations unless widely used in the medical literature, e.g., HIV.
Never use the word “other” as an alternative to another value set.
  • For example, do not name a value set "Other Endophthalmitis" just because a value set named "Purulent Endophthalmitis" already exists. Be as specific as possible. "Other Endophthalmitis" lacks adequate information value set users need.
  • Non-purulent Endophthalmitis could be a better name to indicate another type of Endophthalmitis.
Renaming
  • Rename a published value set to add clarity to the name and update the version of the value set.
  • If there is a change to the description, intent, or content, consider the need to create a new value set.
  • Correct the name if not able to align the value set content with the initial name given to the value set. For example, if initially named "Oral Anticoagulants" when the intent was to capture only oral anticoagulants for chronic atrial fibrillation, change the name to "Oral Anticoagulants for Chronic Atrial Fibrillation" to align it with the intended purpose.
Value Set Description

High-quality value sets provide a clear and comprehensive description of the constituent concepts of the value set including the intent or use of the value set. In the VSAC, a purpose statement has four components (clinical focus, data element scope, inclusion, and exclusion criteria) to provide information a value set user can use to understand the content, the use of the value set, and the scope or breadth of concepts for inclusion or exclusion in the value set. Currently, the VSAC does not require a purpose statement to publish a value set, however, it is best practice to include a purpose statement with all four components completed for a published value set.

If the value set author meaningfully changes the focus or intent of the value set, the value set author should evaluate for continued appropriateness as fit for purpose. If not found consistent with the original focus or intent, the value set author should consider creating a new value set.

 

Purpose Statement ComponentGuidance
Clinical Focus

Clinical Focus is a required text statement describing the general focus of the value set including a description of the intended constituent concepts. The Clinical Focus can include information about clinical relevancy, or a statement about the general focus of the value set, such as a description of types of messages, payment options, or geographic locations. The statement should be written as a full sentence with end punctuation (period). Over the course of a value set’s lifecycle, the measure developer should not change the clinical focus in any meaningful way.

Format: The purpose of this value set is to [verb] concepts for/of [noun(s)].

  • Appropriate verbs
    • Identify
    • Represent
    • Describe
    • Define
    • Group

Example: The purpose of this value set is to represent concepts for a diagnosis of type I diabetes mellitus.

Data Element Scope

Data Element Scope is a required text statement describing how the data element relates to the value set to which it is bound. This context of use often constrains the semantic type of the allowed constituent concepts. The value set author should write the statement as a full sentence with end punctuation (period).

Format: This value set may use a model element in the [Quality Data Model (QDM) or other data model category].

Example: This value set may use a model element in the QDM category of Medication.

Inclusion Criteria

Inclusion Criteria is a required text statement that describes the concept or code criteria the value set author included. The statement should be a full sentence with end punctuation (period).

Format: Includes concepts that [verb] [description].

  • Appropriate verbs
    • Identify
    • Represent
    • Describe
    • Define
    • Group
  • Examples of the form of the description
    • a diagnosis of
    • a procedure for
    • an encounter for/specific to
    • a medication for

Example: Includes concepts that describe a medication specific to generic, prescribable esterified estrogen medication.

Note: The value set author can provide an optional inclusion criteria statement when a value set has members that are not currently active in the code system (legacy codes) used to build the value set. This optional statement will allow VSAC users to have more information about the use and intent of the value set. This information may help a user determine if the value set would meet their needs or if the inclusion of inactive codes would not be appropriate for their use. Value set authors should include the statement in the inclusion criteria component of the purpose statement of the grouping value set containing the extensional value set with the inactive concepts. The recommendation is to use the statement, "Includes concepts that may no longer be valid in the code system of choice to facilitate lookback periods" to indicate inactive concepts are in the value set.

Format: Includes concepts that may no longer be valid in the code system of choice to facilitate lookback periods.

Exclusion Criteria

Exclusion Criteria is an optional text statement describing what specific concept(s) or code criteria the measure developer would normally include, but specifically excluded and why. The statement should include end punctuation (period). It is good practice to populate this field with “No exclusions” if there are no exclusions.

Format: Excludes concepts that [verb] [description].

  • Appropriate verbs
    • Identify
    • Represent
    • Describe
    • Define
    • Group

Example: Excludes concepts representing medications used to treat diabetes mellitus but are not commonly associated with severe hypoglycemia.

Value Set Content

The standardization of value sets is important, as it improves data comparison across programs, measures, or data sets. Adherence to quality criteria facilitates the reuse of well-defined value sets to advance research studies and promotes the interoperability of health-related systems. Value set authors should clearly understand major principles defining high-quality value sets. These guidelines will help to advance data sharing by helping to standardize and define the content of extensional, intensional, and grouping value sets.

ContentGuidance
ValidityValue set authors should ensure all included concepts correspond to the intent and purpose of the value set. Users of value sets should review and consider subtle nuances of the concepts in clinical or administrative meaning.
Metadata CompletenessValue sets have important metadata to understand the scope of meaning for the included concepts and the intended use, identity, and ownership. It is best practice to include value set name and purpose statement
Non-redundancyWhere possible, each value set should have a clear purpose fitting the desired program use. Multiple value sets with the same scope and use should be avoided particularly if the redundant value sets are used by the same program.
Code List CompletenessA value set should contain all the relevant concepts for a particular data element. Value set authors should ensure the lists are lean and should scrutinize large value sets.
Logical CorrectnessA value set should contain only the relevant concepts for a selected data element and the concepts contained in the value set should strictly align with the described purpose.
Concept Property SimilarityValue set member concepts should not vary with respect to their properties and attributes, such as semantic type and term type. For example, a value set intended for prescribable drugs should contain only drugs with the property "Prescribable." This is applicable to concepts that have such properties. The properties should be more similar than dissimilar. For complex cases, value set authors should seek guidance from terminology experts.
Value Set Review and Maintenance

Value set users expect a value set’s author and/or steward to review and update their value set as terminology, clinical standards, evidence or guidelines, and program needs change over time. The appropriate application of VSAC review and maintenance statuses will increase transparency to the value set’s review and maintenance activities. Table 1 provides value set review and maintenance components and considerations.

Table 1. Value Set Review and Maintenance Components and Considerations
MaintenanceGuidance & Considerations
Frequency of Review

At a minimum, value set authors and stewards should review their value set(s) contents annually and base the review on program or use requirements. Contents may include specific value set codes, value set purpose, or review and maintenance status.

For example, authors and stewards should review new codes or legacy codes that may be appropriate to add, depending on the terminology, and review inactive codes for removal or retention. 

Review and Maintenance Status

A review and maintenance status for a value set is available in VSAC in both the authoring and public search tabs.

  • In the public Search Value Sets tab, find the review and maintenance status in section C. Value Set Expansions. For each value set, the Value Set Details tab has a Metadata tab providing Expansion Details with more information on the expansion profile and the review and maintenance status descriptions.
  • In the Authoring tab, find the review and maintenance status under the column titled Review Status. For each value set, the Review/Maintenance tab provides the ability to update the review and maintenance status.

All value set review and maintenance statuses begin with the publication of the value set. A published value set will have one of five review and maintenance statuses:

  • Active
  • Not Maintained
  • Deprecated
  • Retired
  • Experimental

See Table 2 for more information on review and maintenance statuses.

Use

In VSAC, a value set author and steward can track the number of value set downloads to approximate use of the value set. An increase in downloads of a value set may be an indication of a value set’s use (see Value Set Usage Summary for Authors and Stewards for additional details).

  • The usage summary provides the number of downloads of the value set. Value set authors and stewards can apply the usage summary to approximate the use of the value set. The usage summary can assist the stewards and authors to make decisions regarding continued maintenance and assigning a particular maintenance status.
Transfer of Stewardship

If a steward no longer wants to maintain a value set that is used, stewards can transfer ownership of a value set directly to another steward in VSAC.

  • All value sets in VSAC have a Contact Steward icon for Unified Medical Language System (UMLS) licensed users to contact the value set steward on record to request transfer of stewardship of the value set. Both parties must agree to the transfer of the stewardship for a value set. After agreement, the stewardship can be changed using the VSAC Change Value Set Ownership function.
  • If the steward is not available to transfer stewardship through VSAC, the National Library of Medicine (NLM) can make the transfer. The user requesting stewardship transfer can send an email to nlm-support@nlm.nih.gov

A. Value Set Review and Maintenance Statuses Guidance

The value set author and steward uses the review and maintenance status of a value set to

  • inform value set users the value set is being maintained
  • help users make decisions on potential use or reuse of a value set
  • provide transparency of the review and maintenance activities

The review and maintenance status also shows measure implementers and users the value set is likely to contain up-to-date content appropriate for a certain use when it has an active status.

As the author and steward updates the value set, certain guidance applies to the status: 

  • The value set review and maintenance status applies to a single, specific value set definition version, and not “all versions” of a value set.
  • The value set review and maintenance status does not apply to the use of a value set in a specific program.
  • Value Set Review Status and Maintenance History tracks the last date on which the author or steward reviewed the value set metadata, definition, or expansion.

The value set review and maintenance statuses are Active, Experimental, Not Maintained, Deprecated, and Retired. The VSAC does not currently have business rules on timings to transition a value set from Not Maintained to Deprecated, or from Deprecated to Retired. However, there is automatic transition timing from Active to Not Maintained.

The VSAC Support Center provides definitions for each value set review and maintenance status. For additional information and considerations on each review and maintenance status, refer to the guidance in Table 2.

Table 2: Value Set Review and Maintenance Status Guidance
Review and Maintenance StatusGuidance and Considerations
Active

The Active status indicates a value set underwent review and maintenance, if deemed necessary by the steward or author. The value set will remain as Active in VSAC if a value set author or steward either

  • Publishes a new definition version of a value set
  • Selects the “Mark as Reviewed” button, which restarts the value set review and maintenance cycle timeline. Value set authors and stewards can check “Mark as Reviewed” anytime. This option is always available for value set authors and stewards to indicate they have reviewed a value set.

To keep a value set in Active status, the author and/or steward should review their value set at least every 12 months. Reviews should be based on the value set’s code system updates, content alignment with intent, potential clinical evidence changes, and end user feedback.

If the value set author or steward has not marked the value set as reviewed or re-published after 12 months, NLM will send monthly email notifications for a total of 5 months thereafter. Hence, re-publishing or marking a value set as reviewed will keep the status active for a total of 17 months.

Value sets used in CMS or other federal health programs or currently utilized in systems should have an Active status. Even in the event a value set uses a code system the owner (e.g., National Center for Health Statistics) is no longer updating (e.g., ICD-9-CM), the value set author and/or steward should still review the value set for continued use and mark as reviewed if the value set is still applicable for its intended purpose.

Not Maintained

An author or steward should mark a value set as Not Maintained if they do not plan to review, update, re-publish, use, or otherwise follow any maintenance process for their value set. In addition, an automated process can assign this status when the author or steward does not complete actions to keep the value set in an active status and there is no record of review or maintenance for 17 months.

  • VSAC will send value set review and maintenance notifications when a value set author or steward does not perform any review or maintenance within the past year.
  • Based on timing of review and update cycles, in some situations, the steward or author may include a Not Maintained version in a current program release if a value set author or steward fails to complete an annual review and maintain an Active value set status.
  • If a value set goes to a Not Maintained status, neither NLM nor the value set author or steward can change the value set’s review status back to Active.
  • The value set author or steward must create and publish a new definition version to update the value set status.
    • If creating a new version of a Not Maintained value set, the value set author or steward should use best practices in value set creation, review, and maintenance, which includes reviewing the value set’s contents and purpose.

Expansions cannot be created for value set definitions with this status (see Section C for more information on expansions).

Deprecated

Value sets users should not use a value set with a Deprecated status for any use. When a value set is set to Deprecated status, all previous versions of the value set will also be set to Deprecated.

  • A deprecated value set’s contents are no longer relevant and value set users should not use the value set. For example, there may have been updates to a clinical guideline changing the clinical purpose and content drastically, a value set author or steward may select to deprecate the value set.

The value set author or steward cannot change the Deprecated status to Not Maintained or Active. The value set author and/or steward must create and publish a new definition version and review and update the content accordingly. Expansions cannot be created for value set definitions with this status.

Retired

Value sets users should not use a value set with a Retired status for any use. When a value set is set to Retired status, all previous versions of the value set will also be set to Retired.

  • A retired value set may include relevant content but may be set to Retired by an author or steward because they have chosen to no longer maintain the value set. For example, they may no longer use the value set and are not aware of any other continued use of it.

The value set author or steward cannot change the Retired status to Not Maintained or Active. The value set author and/or steward must create and publish a new definition version. If a value set author or steward determines they will no longer maintain a value set, they may opt to change the value set to the Retired status. Expansions cannot be created for value set definitions with this status.

Experimental

Value sets in Experimental status follow the same review timeline as Active value sets.

  • Value set users should not use a value set in Experimental status except in the context of piloted use.

Value set authors and stewards cannot change the status of a published definition version with the Experimental status.

B. Grouping and Member Review and Maintenance

A grouping value set may contain a value set with a status of Not Maintained and continue to have the Active status. Currently, there is no warning or functionality to notify a value set author or steward that a grouping value set they own now has a Not Maintained value set as a member or keep them from adding a Not Maintained value set to a grouping value set.

It is up to the value set author and/or steward to ensure a grouping value set contains the correct content. It is possible an Active grouping value set contains one or more value set(s) with a Not Maintained status. A user, such as the grouping value set’s steward, may use the Contact Steward button to reach the steward of the Not Maintained extensional value set(s) for more information. If the steward indicates they will not review and maintain the value set(s), upon request, the value set steward may transfer stewardship (see Table 1). After completion of transfer of stewardship, the new value set steward should review the value set, following best practices, and create and publish a new definition.

C. Value Set Expansions

A value set expansion is the set of concept codes (the member set) end users download and implement in systems. An expansion member set is the result of using specified version(s) of a code system, applied to a specified value set definition. The NLM generates the expansion using the most currently available code system and value set version. NLM marks this expansion as "Latest."

In the VSAC, a download of a value set expansion version will include the member set expansion list with the codes, code descriptions, the code system name, identifier, and the code system version used for each member in the expansion set. Note, in VSAC, the NLM uses the status of the value set definition to create the "expansion status" of the expansion. This is true when the expansion was created in the past, the expansion status will change to align with the status of the definition at the time of viewing or download.

Identification of Codes and Code Systems for Value Sets
TopicGuidance
All Value Set Codes Are Active in the Code SystemThe value set authors should consider only currently active codes for inclusion into a value set unless they have intentionally included inactive codes in the value set to facilitate a look-back period. This ensures proper maintenance of the value sets.
Descriptors Match Code System DescriptorsValue set authors should make sure any concept descriptions manually added to value sets match the descriptions in the code system to which the concepts belong. The VSAC Authoring Tool provides a descriptor match check as a built-in function. The VSAC Authoring Tool performs this validation during batch import of codes into a value set and during manual insertions of codes and descriptors.
Terminological CorrectnessEnsure the value set’s concepts align with the appropriate terminology to represent the data element. When a code system groups concepts into distinct hierarchies, the presence of codes rooted in multiple distinct hierarchies may indicate an incorrect choice of codes. In complex cases, value set authors should consult terminology experts.
Code System Alignment to StandardsValue set authors should base their value set on the code system(s) recommended by the standards depending on the purpose of their value set and the data model (such as the QDM) to which the value set authors may be adhering.
Value Set Harmonization

Value set harmonization is the process of eliminating unnecessary variance between highly similar or duplicative value sets. Duplicative or highly similar value sets are two or more value sets with the same intent as defined by the value set title or purpose statements and containing duplicate concepts. Having highly similar or duplicative value sets can cause confusion and added burden to end users.

Results of value set harmonization may include alterations in one or more of the highly similar value sets to accommodate a new use, e.g., a new measure, or determining the need for separate value sets (including creating a new value set) and explicitly stating the needed differences. This may require the value set author/steward to update the value set metadata. Examples of reasons there may be a need for highly similar, but separate value sets are

different intents for value set use one value set may include an exclusion of the other value set, e.g., one value set includes gestational diabetes, but gestational diabetes is an exclusion of the other value set

 

Note that value set repositories other than the VSAC exist and may contain value sets and search capabilities for viewing similarities and differences.

Harmonization Use Cases

There are different value set harmonization use cases.

Value Set Development: When a measure/clinical decision support developer or value set author has a new measure or other need for a value set, they should first look for an existing value set for possible reuse. This is the beginning of harmonization. If an existing value set or values sets is/are close to meeting their needs, they should contact the existing value set steward(s) to discuss making changes to meet the needs of both.

Value Set Updating: When one value set author is updating their value set and finds a highly similar value set, they can reach out to the author/steward of the other value set to see if they can come to a mutual agreement so only one value set is necessary.

Value Set Review for Other Purposes: Occasionally non-value set stewards/authors review value sets, e.g., for research, and identify highly similar value sets. The researchers should review the potentially duplicative value sets, looking for similarities and differences and contact the value set stewards and encourage harmonizing the highly similar value sets or renaming the non-similar value sets.

In each case, the harmonization activity involves the value set stewards/authors of the highly similar value sets communicating and determining if there is a need for separate value sets. If the value set steward is unavailable or indicates they are no longer interested in maintaining the value set, the exploring value set author could ask to take over as steward. If the value set steward is no longer available or does not respond to requests for correspondence, the exploring value set author could contact the NLM Support Center Help Desk explaining they would like to take over responsibility for the value set. Alternatively, the exploring value set author could create a new value set.

Looking for value set similarities and differences

The Value Set Authority Center has a Value Set Comparison Tool to help value set authors compare published extensional, grouping, and intentional expansions of value sets.

Concepts with LOINC Status of "Discouraged"
  • Logical Observation Identifiers, Names and Codes (LOINC) is a common language (set of identifiers, names, and codes) for identifying health measurements, observations, and documents.
  • Concepts with a LOINC status of "Discouraged" remain Active in the Value Set Authority Center (VSAC), but the concept is not recommended by LOINC for current use. Discouraged concepts may appear in records and should not be automatically removed from value sets due to this status. Wherever possible, the superseding concept is indicated in the MAP_TO field of the MapTo Table (see Appendix A) and should be used instead.
  • VSAC also flags inactive/invalid remapped codes in the VSAC Collaboration Tool with remapping information generated for each electronic clinical quality measure (eCQM) and in the VSAC browser Validation function.
  • Value set authors should find remapped codes, as indicated in the VSAC Collaboration spreadsheets and VSAC browser Validation function. Using terminology knowledge, determine how to act on remapped codes. Not all terminology-remapped codes are necessarily inactive or invalid, and not all need to be replaced, depending on the value set author's judgment.

For more information, please see the VSAC Updating Value Sets page, Section V. View Remap Info (for RxNorm, LOINC, and SNOMEDCT value sets only) in the VSAC Support Center.

 

Last Updated: Aug 12, 2024