Back to top
Top
U.S. flag

An official website of the United States government

Excessive Radiation Dose or Inadequate Image Quality for Diagnostic Computed Tomography (CT) in Adults (Facility IQR)

eCQM Compare View

Compare Versions of: "Excessive Radiation Dose or Inadequate Image Quality for Diagnostic Computed Tomography (CT) in Adults (Facility IQR)"

The Compare function compares two years of the measure specifications found in the header of the measure's HTML. It does not include a comparison of any information in the body of the HTML, e.g., population criteria, Clinical Quality Language, or value sets.

Strikethrough text highlighted in red indicates information changed from the previous version. Text highlighted in green indicates information updated in the new eCQM version.

Compare 2025 version to

Table Options
Measure Information 2025 Reporting Period
Title Excessive Radiation Dose or Inadequate Image Quality for Diagnostic Computed Tomography (CT) in Adults (Facility IQR)
CMS eCQM ID CMS1074v2
Short Name

IP-ExRad

CBE ID* 3663e
Measure Steward Alara Imaging, Inc.
Description

This measure provides a standardized method for monitoring the performance of diagnostic CT to discourage unnecessarily high radiation doses, a risk factor for cancer, while preserving image quality. This measure is expressed as a percentage of CT exams that are out-of-range based on...

Show more >
Measure Scoring Proportion measure
Measure Type Intermediate Clinical Outcome
Stratification

None

Risk Adjustment

None

Rationale

Diagnostic imaging using CT occurs in more than a third of acute care hospitalizations in the U.S. (Vance, 2013) and greater than 90 million scans are performed annually in the U.S. (IMV, 2019 ). There is marked observed variation in the radiation doses used to perform these exams...

Show more >
Clinical Recommendation Statement

The measure aligns with numerous evidence- and consensus-based clinical guidelines asking radiologists to track, optimize, and lower CT radiation doses, guidelines that have been written by the American College of Radiology (Kanal, 2017), cardiovascular imaging societies (Hirshfeld,...

Show more >
Improvement Notation

Lower score indicates higher quality, and a decreased score over time indicates improvement

Definition

CT Dose and Image Quality Category: reflects the type of exam performed based on body region and clinical indication. Each CT Dose and Image Quality Category has a specific set of dose and image quality (global noise) thresholds.

Calculated CT Size-Adjusted Dose: reflects the total...

Show more >
Guidance

This is an inverse measure; as such the higher the value the worse the performance.

The level of aggregation for this eCQM is the facility. A parallel eCQM measures CT exams aggregated at the level of the clinician or clinician group. A single CT exam may be simultaneously measured in...

Show more >
Initial Population

All CT scans in adults aged 18 years and older at the start of the measurement period that have a CT Dose and Image Quality Category and were performed during an inpatient hospitalization during the measurement period

Denominator

Equals Initial population with a CT Dose and Image Quality Category, a Calculated Global Noise value, and a Calculated CT Size-Adjusted Dose value

Denominator Exclusions

Denominator, where a CT scan with a CT Dose and Image Quality Category = full body

Numerator

Calculated CT Size-Adjusted Dose greater than or equal to a threshold specific to the CT Dose and Image Quality Category, or Calculated CT Global Noise value greater than or equal to a threshold specific to the CT Dose and Image Quality Category

Numerator Exclusions

Not Applicable

Denominator Exceptions

None

Next Version
Previous Version No Version Available
Last Updated: May 06, 2025