CMS Measure ID: CMS1317v1    Performance/Reporting Period: 2028    CBE ID: Not Applicable
Description:

Percentage of patients aged 18 and older at the beginning of the measurement period with at least one hospital inpatient discharge during the measurement period, who have either an advance care planning (ACP) document in the medical record before the end of an encounter, a do not resuscitate (DNR) order coded in the medical record during an encounter, or documentation of an ACP discussion resulting in a documented decision in the medical record during an encounter.

Data Elements and coded QDM Attributes contained within the eCQM

+ Expand all

Value Set Description from VSAC
Clinical Focus: This value set contains concepts that represent advance directive documentation.
Data Element Scope: This value set may use the Quality Data Model category related to documentation.
Inclusion Criteria: Includes only relevant concepts associated with advance directive documentation.
Exclusion Criteria: Excludes concepts that pertain to any other type of documentation.

Constrained to codes in the Advance Directive Documentation value set (2.16.840.1.113762.1.4.1170.43)

QDM Datatype and Definition

"Assessment, Performed"

Data elements that meet criteria using this datatype should document completion of the assessment indicated by the QDM category and its corresponding value set.

Timing:

  • relevant dateTime references timing for an assessment that occurs at a single point in time.
  • relevant Period references a start and stop time for an assessment that occurs over a time interval
  • author dateTime references the time the action was recorded.
  • Refer to the eCQM expression to determine allowable timings to meet measure criterion.

Note: negation rationale indicates a one-time documentation of a reason an activity is not performed. Negation of QDM datatype-related actions for a reason always use the author dateTime attribute to reference timing and must not use relevantPeriod.

Direct Reference Code

Constrained to Goals, preferences, and priorities for medical treatment LOINC code

QDM Datatype and Definition

"Assessment, Performed"

Data elements that meet criteria using this datatype should document completion of the assessment indicated by the QDM category and its corresponding value set.

Timing:

  • relevant dateTime references timing for an assessment that occurs at a single point in time.
  • relevant Period references a start and stop time for an assessment that occurs over a time interval
  • author dateTime references the time the action was recorded.
  • Refer to the eCQM expression to determine allowable timings to meet measure criterion.

Note: negation rationale indicates a one-time documentation of a reason an activity is not performed. Negation of QDM datatype-related actions for a reason always use the author dateTime attribute to reference timing and must not use relevantPeriod.

Value Set Description from VSAC
Clinical Focus: The purpose of this value set is to define concepts for documentation of portable medical orders
Data Element Scope: This value set may use a model element related to QDM.
Inclusion Criteria: Includes concepts that define documentation of portable medical orders.
Exclusion Criteria: Excludes concepts that define anything other than documentation of portable medical orders.

Constrained to codes in the Portable Medical Order Documentation value set (2.16.840.1.113762.1.4.1170.48)

QDM Datatype and Definition

"Assessment, Performed"

Data elements that meet criteria using this datatype should document completion of the assessment indicated by the QDM category and its corresponding value set.

Timing:

  • relevant dateTime references timing for an assessment that occurs at a single point in time.
  • relevant Period references a start and stop time for an assessment that occurs over a time interval
  • author dateTime references the time the action was recorded.
  • Refer to the eCQM expression to determine allowable timings to meet measure criterion.

Note: negation rationale indicates a one-time documentation of a reason an activity is not performed. Negation of QDM datatype-related actions for a reason always use the author dateTime attribute to reference timing and must not use relevantPeriod.

Value Set Description from VSAC
Clinical Focus: The purpose of this value set is to represent concepts for encounters in the emergency department (ED).
Data Element Scope: This value set may use a model element related to Encounter.
Inclusion Criteria: Includes concepts that represent an encounter ocurring in the emergency department (ED).
Exclusion Criteria: Excludes concepts that represent services not performed in the emergency department, including critical care and observation services.

Constrained to codes in the Emergency Department Visit value set (2.16.840.1.113883.3.117.1.7.1.292)

QDM Datatype and Definition

"Encounter, Performed"

Data elements that meet criteria using this datatype should document that the encounter indicated by the QDM category and its corresponding value set is in progress or has been completed.

The "Encounter, Performed" participant references the primary participant.

Previous versions of QDM included an attribute principal diagnosis, defined as the condition that, after study, was determined to be the principal cause of the admission. QDM version 5.6 addresses that concept using the diagnosis rank=1.

Timing:

  • The relevantPeriod addresses:
    • startTime - The time the encounter began (admission time).
    • stopTime - The time the encounter ended (discharge time).
  • author dateTime references the time the action was recorded.
  • Refer to the eCQM expression to determine allowable timings to meet measure criteria.

Notes:

  • negation rationale indicates a one-time documentation of a reason an activity is not performed. Negation of QDM datatype-related actions for a reason always use the author dateTime attribute to reference timing and must not use relevantPeriod.
  • The locationPeriod is an attribute of the attribute facility location that addresses:
    • startTime - the time the patient arrived at the location. The time the encounter began (admission time).
    • stopTime - the time the patient departed from the location.
Value Set Description from VSAC
Clinical Focus: The purpose of this value set is to represent concepts of inpatient hospitalization encounters.
Data Element Scope: This value set may use a model element related to Encounter.
Inclusion Criteria: Includes concepts that represent an encounter for elective and non-elective inpatient hospitalizations.
Exclusion Criteria: No exclusions.

Constrained to codes in the Encounter Inpatient value set (2.16.840.1.113883.3.666.5.307)

QDM Datatype and Definition

"Encounter, Performed"

Data elements that meet criteria using this datatype should document that the encounter indicated by the QDM category and its corresponding value set is in progress or has been completed.

The "Encounter, Performed" participant references the primary participant.

Previous versions of QDM included an attribute principal diagnosis, defined as the condition that, after study, was determined to be the principal cause of the admission. QDM version 5.6 addresses that concept using the diagnosis rank=1.

Timing:

  • The relevantPeriod addresses:
    • startTime - The time the encounter began (admission time).
    • stopTime - The time the encounter ended (discharge time).
  • author dateTime references the time the action was recorded.
  • Refer to the eCQM expression to determine allowable timings to meet measure criteria.

Notes:

  • negation rationale indicates a one-time documentation of a reason an activity is not performed. Negation of QDM datatype-related actions for a reason always use the author dateTime attribute to reference timing and must not use relevantPeriod.
  • The locationPeriod is an attribute of the attribute facility location that addresses:
    • startTime - the time the patient arrived at the location. The time the encounter began (admission time).
    • stopTime - the time the patient departed from the location.
Value Set Description from VSAC
Clinical Focus: The purpose of this value set is to represent concepts for encounters for observation.
Data Element Scope: This value set may use a model element related to Encounter.
Inclusion Criteria: Includes concepts that represent an encounter for observation in the inpatient or outpatient setting.
Exclusion Criteria: No exclusions.

Constrained to codes in the Observation Services value set (2.16.840.1.113762.1.4.1111.143)

QDM Datatype and Definition

"Encounter, Performed"

Data elements that meet criteria using this datatype should document that the encounter indicated by the QDM category and its corresponding value set is in progress or has been completed.

The "Encounter, Performed" participant references the primary participant.

Previous versions of QDM included an attribute principal diagnosis, defined as the condition that, after study, was determined to be the principal cause of the admission. QDM version 5.6 addresses that concept using the diagnosis rank=1.

Timing:

  • The relevantPeriod addresses:
    • startTime - The time the encounter began (admission time).
    • stopTime - The time the encounter ended (discharge time).
  • author dateTime references the time the action was recorded.
  • Refer to the eCQM expression to determine allowable timings to meet measure criteria.

Notes:

  • negation rationale indicates a one-time documentation of a reason an activity is not performed. Negation of QDM datatype-related actions for a reason always use the author dateTime attribute to reference timing and must not use relevantPeriod.
  • The locationPeriod is an attribute of the attribute facility location that addresses:
    • startTime - the time the patient arrived at the location. The time the encounter began (admission time).
    • stopTime - the time the patient departed from the location.
Value Set Description from VSAC
Clinical Focus: This value set contains concepts that are used to identify outpatient surgery encounter types.
Data Element Scope: This value set may use Quality Data Model (QDM) category related to Encounter, Performed. The intent of this data element is to identify patients who have had an outpatient surgery encounter.
Inclusion Criteria: Includes only relevant concepts associated with SNOMED codes identifying outpatient surgery encounters.
Exclusion Criteria: No exclusions.

Constrained to codes in the Outpatient Surgery Service value set (2.16.840.1.113762.1.4.1110.38)

QDM Datatype and Definition

"Encounter, Performed"

Data elements that meet criteria using this datatype should document that the encounter indicated by the QDM category and its corresponding value set is in progress or has been completed.

The "Encounter, Performed" participant references the primary participant.

Previous versions of QDM included an attribute principal diagnosis, defined as the condition that, after study, was determined to be the principal cause of the admission. QDM version 5.6 addresses that concept using the diagnosis rank=1.

Timing:

  • The relevantPeriod addresses:
    • startTime - The time the encounter began (admission time).
    • stopTime - The time the encounter ended (discharge time).
  • author dateTime references the time the action was recorded.
  • Refer to the eCQM expression to determine allowable timings to meet measure criteria.

Notes:

  • negation rationale indicates a one-time documentation of a reason an activity is not performed. Negation of QDM datatype-related actions for a reason always use the author dateTime attribute to reference timing and must not use relevantPeriod.
  • The locationPeriod is an attribute of the attribute facility location that addresses:
    • startTime - the time the patient arrived at the location. The time the encounter began (admission time).
    • stopTime - the time the patient departed from the location.
Direct Reference Code

Constrained to Do not resuscitate ICD10CM code

QDM Datatype and Definition

"Intervention, Order"

Data elements that meet criteria using this datatype should document a request to perform the intervention indicated by the QDM category and its corresponding value set.

Timing: The time the order is signed; author dateTime.

Note: negation rationale indicates a one-time documentation of a reason an activity is not performed. Negation of QDM datatype-related actions for a reason always use the author dateTime attribute to reference timing and must not use relevantPeriod.

Value Set Description from VSAC
Clinical Focus: This value set contains concepts that represent advance care planning documentation.
Data Element Scope: This value set may use the Quality Data Model category related to documentation.
Inclusion Criteria: Includes only relevant concepts associated with advance care planning documentation
Exclusion Criteria: Excludes concepts that pertain to any type of documentation other than for advance care planning.

Constrained to codes in the Advance Care Planning Documentation value set (2.16.840.1.113762.1.4.1170.45)

QDM Datatype and Definition

"Intervention, Performed"

Data elements that meet criteria using this datatype should document the completion of the intervention indicated by the QDM category and its corresponding value set.

Timing:

  • relevant dateTime references the time the intervention is performed when the intervention occurs at a single point in time.
  • relevantPeriod references a start and stop time for an intervention that occurs over a time interval. relevantPeriod addresses:
    • startTime - The time the intervention begins.
    • stopTime - The time the intervention ends.
  • author dateTime references the time the action was recorded.
  • Refer to the eCQM expression to determine allowable timings to meet measure criterion.

Notes:

  • Timing refers to a single instance of an intervention. If a measure seeks to evaluate multiple interventions over a period of time, the measure developer should use CQL logic to represent the query request.
  • negation rationale indicates a one-time documentation of a reason an activity is not performed. Negation of QDM datatype-related actions for a reason always use the author dateTime attribute to reference timing and must not use relevantPeriod.
Value Set Description from VSAC
Clinical Focus: This value set contains concepts that represent advance directive documentation.
Data Element Scope: This value set may use the Quality Data Model category related to documentation.
Inclusion Criteria: Includes only relevant concepts associated with advance directive documentation.
Exclusion Criteria: Excludes concepts that pertain to any other type of documentation.

Constrained to codes in the Advance Directive Documentation value set (2.16.840.1.113762.1.4.1170.43)

QDM Datatype and Definition

"Intervention, Performed"

Data elements that meet criteria using this datatype should document the completion of the intervention indicated by the QDM category and its corresponding value set.

Timing:

  • relevant dateTime references the time the intervention is performed when the intervention occurs at a single point in time.
  • relevantPeriod references a start and stop time for an intervention that occurs over a time interval. relevantPeriod addresses:
    • startTime - The time the intervention begins.
    • stopTime - The time the intervention ends.
  • author dateTime references the time the action was recorded.
  • Refer to the eCQM expression to determine allowable timings to meet measure criterion.

Notes:

  • Timing refers to a single instance of an intervention. If a measure seeks to evaluate multiple interventions over a period of time, the measure developer should use CQL logic to represent the query request.
  • negation rationale indicates a one-time documentation of a reason an activity is not performed. Negation of QDM datatype-related actions for a reason always use the author dateTime attribute to reference timing and must not use relevantPeriod.
Value Set Description from VSAC
Clinical Focus: This value set contains concepts that represent the existence of healthcare agent and power of attorney documentation
Data Element Scope: This value set may use the Quality Data Model category related to documentation.
Inclusion Criteria: Includes only concepts related to healthcare agent and power of attorney documentation.
Exclusion Criteria: Excludes concepts that pertain to other forms of documentation.

Constrained to codes in the Healthcare Agent and Power of Attorney Documentation value set (2.16.840.1.113762.1.4.1170.31)

QDM Datatype and Definition

"Intervention, Performed"

Data elements that meet criteria using this datatype should document the completion of the intervention indicated by the QDM category and its corresponding value set.

Timing:

  • relevant dateTime references the time the intervention is performed when the intervention occurs at a single point in time.
  • relevantPeriod references a start and stop time for an intervention that occurs over a time interval. relevantPeriod addresses:
    • startTime - The time the intervention begins.
    • stopTime - The time the intervention ends.
  • author dateTime references the time the action was recorded.
  • Refer to the eCQM expression to determine allowable timings to meet measure criterion.

Notes:

  • Timing refers to a single instance of an intervention. If a measure seeks to evaluate multiple interventions over a period of time, the measure developer should use CQL logic to represent the query request.
  • negation rationale indicates a one-time documentation of a reason an activity is not performed. Negation of QDM datatype-related actions for a reason always use the author dateTime attribute to reference timing and must not use relevantPeriod.
Value Set Description from VSAC
Clinical Focus: The purpose of this value set is to define concepts for documentation of portable medical orders
Data Element Scope: This value set may use a model element related to QDM.
Inclusion Criteria: Includes concepts that define documentation of portable medical orders.
Exclusion Criteria: Excludes concepts that define anything other than documentation of portable medical orders.

Constrained to codes in the Portable Medical Order Documentation value set (2.16.840.1.113762.1.4.1170.48)

QDM Datatype and Definition

"Intervention, Performed"

Data elements that meet criteria using this datatype should document the completion of the intervention indicated by the QDM category and its corresponding value set.

Timing:

  • relevant dateTime references the time the intervention is performed when the intervention occurs at a single point in time.
  • relevantPeriod references a start and stop time for an intervention that occurs over a time interval. relevantPeriod addresses:
    • startTime - The time the intervention begins.
    • stopTime - The time the intervention ends.
  • author dateTime references the time the action was recorded.
  • Refer to the eCQM expression to determine allowable timings to meet measure criterion.

Notes:

  • Timing refers to a single instance of an intervention. If a measure seeks to evaluate multiple interventions over a period of time, the measure developer should use CQL logic to represent the query request.
  • negation rationale indicates a one-time documentation of a reason an activity is not performed. Negation of QDM datatype-related actions for a reason always use the author dateTime attribute to reference timing and must not use relevantPeriod.
Value Set Description from VSAC
Clinical Focus: n/a Data Element Scope: n/a Inclusion Criteria: n/a Exclusion Criteria: n/a

Constrained to codes in the Ethnicity value set (2.16.840.1.114222.4.11.837)

QDM Datatype and Definition

"Patient Characteristic, Ethnicity"

Data elements that meet criteria using this datatype should document that the patient has one or more of the ethnicities indicated by the QDM category and its corresponding value set.

Timing: Ethnicity does not have a specific timing. Measures using "Patient Characteristic, Ethnicity" should address the most recent entry in the clinical record.

Value Set Description from VSAC
Clinical Focus: Categories of types of health care payer entities as defined by the Centers for Disease Control and Prevention National Center for Health Statistics Source of Payment Codes.
Data Element Scope: Concepts intended to represent categories of insurance (payer) types.
Inclusion Criteria: Codes representing high level categories of insurance (payer) types
Exclusion Criteria: Codes representing, subdivisions of insurance categories and or specific private insurance companies

Constrained to codes in the Payer Type value set (2.16.840.1.114222.4.11.3591)

QDM Datatype and Definition

"Patient Characteristic, Payer"

Data elements that meet criteria using this datatype should document that the patient has one or more of the payers indicated by the QDM category and its corresponding value set.

Timing:

The relevantPeriod addresses:

  • startTime – the first day of insurance coverage with the referenced payer.
  • stopTime – the last day of insurance coverage with the referenced payer.
Value Set Description from VSAC
Clinical Focus: n/a Data Element Scope: n/a Inclusion Criteria: n/a Exclusion Criteria: n/a

Constrained to codes in the Race value set (2.16.840.1.114222.4.11.836)

QDM Datatype and Definition

"Patient Characteristic, Race"

Data elements that meet criteria using this datatype should document the patient’s race.

Timing: Race does not have a specific timing. Measures using "Patient Characteristic, Race" should address the most recent entry in the clinical record.

Value Set Description from VSAC
Clinical Focus: SNOMED CT representations of sex values aligned with US federal administrative requirements across all systems, including quality measure use
Data Element Scope: Patient characteristics
Inclusion Criteria: Limited set of SNOMED CT representations of sex values.
Exclusion Criteria: n/a

Constrained to codes in the Federal Administrative Sex value set (2.16.840.1.113762.1.4.1021.121)

QDM Datatype and Definition

"Patient Characteristic, Sex"

Data elements that meet criteria using this datatype should document that the patient's sex matches the QDM category and its corresponding value set.

Timing: Birth (administrative) sex does not have a specific timing.