CMS Measure ID: CMS135v11    Performance/Reporting Period: 2023    NQF Number: 0081e
Description:

Percentage of patients aged 18 years and older with a diagnosis of heart failure (HF) with a current or prior left ventricular ejection fraction (LVEF) <=40% who were prescribed or already taking ACE inhibitor or ARB or ARNI therapy during the measurement period

Data Elements and coded QDM Attributes contained within the eCQM

+ Expand all

Value Set Description from VSAC
Clinical Focus: The purpose of this value set is to represent concepts for medications of angiotensin-converting enzyme (ACE) inhibitor and angiotensin-receptor blocker (ARB) ingredients.
Data Element Scope: This value set may use a model element related to Allergy/Intolerance.
Inclusion Criteria: Includes concepts that represent an allergy or intolerance for prescribable angiotensin-converting enzyme (ACE) inhibitor and angiotensin-receptor blocker (ARB) ingredients only.
Exclusion Criteria: No exclusions.

Constrained to codes in the Allergy, Intolerance: ACE Inhibitor or ARB Ingredient value set (2.16.840.1.113883.3.526.3.1489)

QDM Datatype and Definition

"Allergy Intolerance"

Data elements that meet criteria using this datatype should document the allergy or intolerance and its corresponding value set.

Timing:

  • The prevalencePeriod references the time from the onset date to the abatement date. Often an abatement date is not present as allergy or intolerance is ongoing.
  • The author dateTime references the recorded time.
Direct Reference Code

Constrained to 'sacubitril' RXNORM code

QDM Datatype and Definition

"Allergy Intolerance"

Data elements that meet criteria using this datatype should document the allergy or intolerance and its corresponding value set.

Timing:

  • The prevalencePeriod references the time from the onset date to the abatement date. Often an abatement date is not present as allergy or intolerance is ongoing.
  • The author dateTime references the recorded time.
Direct Reference Code

Constrained to 'Substance with angiotensin II receptor antagonist mechanism of action (substance)' SNOMEDCT code

QDM Datatype and Definition

"Allergy Intolerance"

Data elements that meet criteria using this datatype should document the allergy or intolerance and its corresponding value set.

Timing:

  • The prevalencePeriod references the time from the onset date to the abatement date. Often an abatement date is not present as allergy or intolerance is ongoing.
  • The author dateTime references the recorded time.
Direct Reference Code

Constrained to 'Substance with angiotensin-converting enzyme inhibitor mechanism of action (substance)' SNOMEDCT code

QDM Datatype and Definition

"Allergy Intolerance"

Data elements that meet criteria using this datatype should document the allergy or intolerance and its corresponding value set.

Timing:

  • The prevalencePeriod references the time from the onset date to the abatement date. Often an abatement date is not present as allergy or intolerance is ongoing.
  • The author dateTime references the recorded time.
Direct Reference Code

Constrained to 'Substance with neprilysin inhibitor mechanism of action (substance)' SNOMEDCT code

QDM Datatype and Definition

"Allergy Intolerance"

Data elements that meet criteria using this datatype should document the allergy or intolerance and its corresponding value set.

Timing:

  • The prevalencePeriod references the time from the onset date to the abatement date. Often an abatement date is not present as allergy or intolerance is ongoing.
  • The author dateTime references the recorded time.
Direct Reference Code

Constrained to 'Acute renal failure caused by angiotensin-converting-enzyme inhibitor (disorder)' SNOMEDCT code

QDM Datatype and Definition

"Diagnosis"

Data elements that meet criteria using this datatype should document the Condition/Diagnosis/Problem and its corresponding value set. The onset dateTime corresponds to the implicit start dateTime of the datatype and the abatement dateTime corresponds to the implicit stop dateTime of the datatype. If the abatement dateTime is not present, then the diagnosis is considered to still be active. When this datatype is used with timing relationships, the criterion is looking for an active diagnosis for the time frame indicated by the timing relationships.

Timing: The prevalencePeriod references the time from the onset date to the abatement date.

Value Set Description from VSAC
Clinical Focus: The purpose of this value set is to represent concepts of diagnosis of allergy to an angiotensin-converting enzyme (ACE) inhibitor and angiotensin-receptor blocker (ARB).
Data Element Scope: This value set may use a model element related to Diagnosis.
Inclusion Criteria: Includes concepts that represent a diagnosis of allergy to an angiotensin-converting enzyme (ACE) inhibitor and angiotensin-receptor blocker (ARB).
Exclusion Criteria: No exclusions.

Constrained to codes in the Diagnosis: Allergy to ACE Inhibitor or ARB value set (2.16.840.1.113883.3.526.3.1211)

QDM Datatype and Definition

"Diagnosis"

Data elements that meet criteria using this datatype should document the Condition/Diagnosis/Problem and its corresponding value set. The onset dateTime corresponds to the implicit start dateTime of the datatype and the abatement dateTime corresponds to the implicit stop dateTime of the datatype. If the abatement dateTime is not present, then the diagnosis is considered to still be active. When this datatype is used with timing relationships, the criterion is looking for an active diagnosis for the time frame indicated by the timing relationships.

Timing: The prevalencePeriod references the time from the onset date to the abatement date.

Value Set Description from VSAC
Clinical Focus: The purpose of this value set is to represent concepts for diagnoses of heart failure.
Data Element Scope: This value set may use a model element related to Diagnosis.
Inclusion Criteria: Includes concepts that represent a diagnosis of heart failure.
Exclusion Criteria: Excludes concepts that represent chronic and acute right-sided heart failure, right heart failure, right ventricular failure, cardiac insufficiency due to prosthesis and following cardiac surgery, or pulmonale.

Constrained to codes in the Diagnosis: Heart Failure value set (2.16.840.1.113883.3.526.3.376)

QDM Datatype and Definition

"Diagnosis"

Data elements that meet criteria using this datatype should document the Condition/Diagnosis/Problem and its corresponding value set. The onset dateTime corresponds to the implicit start dateTime of the datatype and the abatement dateTime corresponds to the implicit stop dateTime of the datatype. If the abatement dateTime is not present, then the diagnosis is considered to still be active. When this datatype is used with timing relationships, the criterion is looking for an active diagnosis for the time frame indicated by the timing relationships.

Timing: The prevalencePeriod references the time from the onset date to the abatement date.

Value Set Description from VSAC
Clinical Focus: The purpose of this value set is to represent concepts related to diagnoses associated with heart transplants.
Data Element Scope: This value set may use a model element related to Diagnosis.
Inclusion Criteria: Includes concepts that represent diagnoses related to heart transplant.
Exclusion Criteria: No exclusions.

Constrained to codes in the Diagnosis: Heart Transplant Related Diagnoses value set (2.16.840.1.113762.1.4.1178.56)

QDM Datatype and Definition

"Diagnosis"

Data elements that meet criteria using this datatype should document the Condition/Diagnosis/Problem and its corresponding value set. The onset dateTime corresponds to the implicit start dateTime of the datatype and the abatement dateTime corresponds to the implicit stop dateTime of the datatype. If the abatement dateTime is not present, then the diagnosis is considered to still be active. When this datatype is used with timing relationships, the criterion is looking for an active diagnosis for the time frame indicated by the timing relationships.

Timing: The prevalencePeriod references the time from the onset date to the abatement date.

Value Set Description from VSAC
Clinical Focus: The purpose of this value set is to represent concepts of diagnoses of intolerance to angiotensin-converting enzyme (ACE) inhibitor or angiotensin II receptor blockers (ARB).
Data Element Scope: This value set may use a model element related to Diagnosis.
Inclusion Criteria: Includes concepts that represent a diagnosis of intolerance to ACE inhibitor or ARB.
Exclusion Criteria: No exclusions.

Constrained to codes in the Diagnosis: Intolerance to ACE Inhibitor or ARB value set (2.16.840.1.113883.3.526.3.1212)

QDM Datatype and Definition

"Diagnosis"

Data elements that meet criteria using this datatype should document the Condition/Diagnosis/Problem and its corresponding value set. The onset dateTime corresponds to the implicit start dateTime of the datatype and the abatement dateTime corresponds to the implicit stop dateTime of the datatype. If the abatement dateTime is not present, then the diagnosis is considered to still be active. When this datatype is used with timing relationships, the criterion is looking for an active diagnosis for the time frame indicated by the timing relationships.

Timing: The prevalencePeriod references the time from the onset date to the abatement date.

Value Set Description from VSAC
Clinical Focus: The purpose of this value set is to represent concepts related to diagnoses associated with left ventricular assist devices.
Data Element Scope: This value set may use a model element related to Diagnosis.
Inclusion Criteria: Includes concepts that represent diagnoses related to heart transplant.
Exclusion Criteria: No exclusions.

Constrained to codes in the Diagnosis: Left Ventricular Assist Device Related Diagnoses value set (2.16.840.1.113762.1.4.1178.58)

QDM Datatype and Definition

"Diagnosis"

Data elements that meet criteria using this datatype should document the Condition/Diagnosis/Problem and its corresponding value set. The onset dateTime corresponds to the implicit start dateTime of the datatype and the abatement dateTime corresponds to the implicit stop dateTime of the datatype. If the abatement dateTime is not present, then the diagnosis is considered to still be active. When this datatype is used with timing relationships, the criterion is looking for an active diagnosis for the time frame indicated by the timing relationships.

Timing: The prevalencePeriod references the time from the onset date to the abatement date.

Direct Reference Code

Constrained to 'Left ventricular systolic dysfunction (disorder)' SNOMEDCT code

QDM Datatype and Definition

"Diagnosis"

Data elements that meet criteria using this datatype should document the Condition/Diagnosis/Problem and its corresponding value set. The onset dateTime corresponds to the implicit start dateTime of the datatype and the abatement dateTime corresponds to the implicit stop dateTime of the datatype. If the abatement dateTime is not present, then the diagnosis is considered to still be active. When this datatype is used with timing relationships, the criterion is looking for an active diagnosis for the time frame indicated by the timing relationships.

Timing: The prevalencePeriod references the time from the onset date to the abatement date.

Value Set Description from VSAC
Clinical Focus: The purpose of this value set is to represent concepts of a diagnosis of moderate or severe left ventricular systolic dysfunction (LVSD).
Data Element Scope: This value set may use a model element related to Diagnosis.
Inclusion Criteria: Includes concepts that represent a diagnosis of moderate or severe LVSD.
Exclusion Criteria: No exclusions.

Constrained to codes in the Diagnosis: Moderate or Severe LVSD value set (2.16.840.1.113883.3.526.3.1090)

QDM Datatype and Definition

"Diagnosis"

Data elements that meet criteria using this datatype should document the Condition/Diagnosis/Problem and its corresponding value set. The onset dateTime corresponds to the implicit start dateTime of the datatype and the abatement dateTime corresponds to the implicit stop dateTime of the datatype. If the abatement dateTime is not present, then the diagnosis is considered to still be active. When this datatype is used with timing relationships, the criterion is looking for an active diagnosis for the time frame indicated by the timing relationships.

Timing: The prevalencePeriod references the time from the onset date to the abatement date.

Value Set Description from VSAC
Clinical Focus: The purpose of this value set is to represent concepts for diagnoses of pregnancy.
Data Element Scope: This value set may use a model element related to Diagnosis.
Inclusion Criteria: Includes concepts that represent a diagnosis of pregnancy.
Exclusion Criteria: No exclusions.

Constrained to codes in the Diagnosis: Pregnancy value set (2.16.840.1.113883.3.526.3.378)

QDM Datatype and Definition

"Diagnosis"

Data elements that meet criteria using this datatype should document the Condition/Diagnosis/Problem and its corresponding value set. The onset dateTime corresponds to the implicit start dateTime of the datatype and the abatement dateTime corresponds to the implicit stop dateTime of the datatype. If the abatement dateTime is not present, then the diagnosis is considered to still be active. When this datatype is used with timing relationships, the criterion is looking for an active diagnosis for the time frame indicated by the timing relationships.

Timing: The prevalencePeriod references the time from the onset date to the abatement date.

Value Set Description from VSAC
Clinical Focus: The purpose of this value set is to represent concepts of diagnostic studies for ejection fraction.
Data Element Scope: This value set may use a model element related to Diagnostic Study.
Inclusion Criteria: Includes concepts that represent a diagnostic study for obtaining left ventricular ejection fraction.
Exclusion Criteria: No exclusions.

Constrained to codes in the Diagnostic Study, Performed: Ejection Fraction value set (2.16.840.1.113883.3.526.3.1134)

QDM Datatype and Definition

"Diagnostic Study, Performed"

Data elements that meet criteria using this datatype should document the completion of the diagnostic study indicated by the QDM category and its corresponding value set.

Timing:

  • relevant dateTime references the time the diagnostic study is performed if it occurs at a single point in time.
  • relevantPeriod references a start and stop time for an assessment that occurs over a time interval:
    • startTime - when the diagnostic study is initiated.
    • stopTime - when the diagnostic study is completed.
  • author dateTime references the time the action was recorded.
  • Refer to the eCQM expression to determine allowable timings to meet measure criterion.

Examples using relevantPeriod:

  • Initiation of a treadmill stress test to the time the treadmill stress test has completed
  • Initiation of the ultrasound study until completion of the ultrasound study

Note: negation rationale indicates a one-time documentation of a reason an activity is not performed. Negation of QDM datatype-related actions for a reason always use the author dateTime attribute to reference timing and must not use relevantPeriod.

Value Set Description from VSAC
Clinical Focus: The purpose of this value set is to represent concepts for encounters for patients living in assisted living, domiciliary care or rest homes.
Data Element Scope: This value set may use a model element related to Encounter.
Inclusion Criteria: Includes concepts that represent an encounter for services provided to new and established patients living in assisted living, domiciliary care or rest home who have had an interaction with a member of their medical team.
Exclusion Criteria: Excludes concepts that represent an encounter for settings other than assisted living, domiciliary care, or rest homes.

Constrained to codes in the Encounter, Performed: Care Services in Long Term Residential Facility value set (2.16.840.1.113883.3.464.1003.101.12.1014)

QDM Datatype and Definition

"Encounter, Performed"

Data elements that meet criteria using this datatype should document that the encounter indicated by the QDM category and its corresponding value set is in progress or has been completed.

The "Encounter, Performed" participant references the primary participant.

Previous versions of QDM included an attribute principal diagnosis, defined as the condition that, after study, was determined to be the principal cause of the admission. QDM version 5.6 addresses that concept using the diagnosis rank=1.

Timing:

  • The relevantPeriod addresses:
    • startTime - The time the encounter began (admission time).
    • stopTime - The time the encounter ended (discharge time).
  • author dateTime references the time the action was recorded.
  • Refer to the eCQM expression to determine allowable timings to meet measure criteria.

Notes:

  • negation rationale indicates a one-time documentation of a reason an activity is not performed. Negation of QDM datatype-related actions for a reason always use the author dateTime attribute to reference timing and must not use relevantPeriod.
  • The locationPeriod is an attribute of the attribute facility location that addresses:
    • startTime - the time the patient arrived at the location. The time the encounter began (admission time).
    • stopTime - the time the patient departed from the location.
Value Set Description from VSAC
Clinical Focus: The purpose of this value set is to represent concepts for encounters for home health visits.
Data Element Scope: This value set may use a model element related to Encounter.
Inclusion Criteria: Includes concepts that represent an encounter for a home health visit for the evaluation and management of a new or established patient.
Exclusion Criteria: No exclusions.

Constrained to codes in the Encounter, Performed: Home Healthcare Services value set (2.16.840.1.113883.3.464.1003.101.12.1016)

QDM Datatype and Definition

"Encounter, Performed"

Data elements that meet criteria using this datatype should document that the encounter indicated by the QDM category and its corresponding value set is in progress or has been completed.

The "Encounter, Performed" participant references the primary participant.

Previous versions of QDM included an attribute principal diagnosis, defined as the condition that, after study, was determined to be the principal cause of the admission. QDM version 5.6 addresses that concept using the diagnosis rank=1.

Timing:

  • The relevantPeriod addresses:
    • startTime - The time the encounter began (admission time).
    • stopTime - The time the encounter ended (discharge time).
  • author dateTime references the time the action was recorded.
  • Refer to the eCQM expression to determine allowable timings to meet measure criteria.

Notes:

  • negation rationale indicates a one-time documentation of a reason an activity is not performed. Negation of QDM datatype-related actions for a reason always use the author dateTime attribute to reference timing and must not use relevantPeriod.
  • The locationPeriod is an attribute of the attribute facility location that addresses:
    • startTime - the time the patient arrived at the location. The time the encounter began (admission time).
    • stopTime - the time the patient departed from the location.
Value Set Description from VSAC
Clinical Focus: The purpose of this value set is to represent concepts for encounters in a nursing facility.
Data Element Scope: This value set may use a model element related to Encounter.
Inclusion Criteria: Includes concepts that represent an encounter specific to a nursing facility, including skilled, intermediate and long term care facilities.
Exclusion Criteria: Excludes concepts that represent an encounter other than a nursing facility visits.

Constrained to codes in the Encounter, Performed: Nursing Facility Visit value set (2.16.840.1.113883.3.464.1003.101.12.1012)

QDM Datatype and Definition

"Encounter, Performed"

Data elements that meet criteria using this datatype should document that the encounter indicated by the QDM category and its corresponding value set is in progress or has been completed.

The "Encounter, Performed" participant references the primary participant.

Previous versions of QDM included an attribute principal diagnosis, defined as the condition that, after study, was determined to be the principal cause of the admission. QDM version 5.6 addresses that concept using the diagnosis rank=1.

Timing:

  • The relevantPeriod addresses:
    • startTime - The time the encounter began (admission time).
    • stopTime - The time the encounter ended (discharge time).
  • author dateTime references the time the action was recorded.
  • Refer to the eCQM expression to determine allowable timings to meet measure criteria.

Notes:

  • negation rationale indicates a one-time documentation of a reason an activity is not performed. Negation of QDM datatype-related actions for a reason always use the author dateTime attribute to reference timing and must not use relevantPeriod.
  • The locationPeriod is an attribute of the attribute facility location that addresses:
    • startTime - the time the patient arrived at the location. The time the encounter began (admission time).
    • stopTime - the time the patient departed from the location.
Value Set Description from VSAC
Clinical Focus: The purpose of this value set is to represent concepts for encounters for an outpatient visit.
Data Element Scope: This value set may use a model element related to Encounter.
Inclusion Criteria: Includes concepts that represent an encounter for the comprehensive history, evaluation, and management of a patient presenting with minor to high severity problems.
Exclusion Criteria: No exclusions.

Constrained to codes in the Encounter, Performed: Office Visit value set (2.16.840.1.113883.3.464.1003.101.12.1001)

QDM Datatype and Definition

"Encounter, Performed"

Data elements that meet criteria using this datatype should document that the encounter indicated by the QDM category and its corresponding value set is in progress or has been completed.

The "Encounter, Performed" participant references the primary participant.

Previous versions of QDM included an attribute principal diagnosis, defined as the condition that, after study, was determined to be the principal cause of the admission. QDM version 5.6 addresses that concept using the diagnosis rank=1.

Timing:

  • The relevantPeriod addresses:
    • startTime - The time the encounter began (admission time).
    • stopTime - The time the encounter ended (discharge time).
  • author dateTime references the time the action was recorded.
  • Refer to the eCQM expression to determine allowable timings to meet measure criteria.

Notes:

  • negation rationale indicates a one-time documentation of a reason an activity is not performed. Negation of QDM datatype-related actions for a reason always use the author dateTime attribute to reference timing and must not use relevantPeriod.
  • The locationPeriod is an attribute of the attribute facility location that addresses:
    • startTime - the time the patient arrived at the location. The time the encounter began (admission time).
    • stopTime - the time the patient departed from the location.
Value Set Description from VSAC
Clinical Focus: The purpose of this value set is to represent concepts for encounters for outpatient interactions with a member of the medical care team.
Data Element Scope: This value set may use a model element related to Encounter.
Inclusion Criteria: Includes concepts that represent an encounter for the comprehensive history, evaluation, and management of a patient presenting with minor to high severity problems.
Exclusion Criteria: No exclusions.

Constrained to codes in the Encounter, Performed: Outpatient Consultation value set (2.16.840.1.113883.3.464.1003.101.12.1008)

QDM Datatype and Definition

"Encounter, Performed"

Data elements that meet criteria using this datatype should document that the encounter indicated by the QDM category and its corresponding value set is in progress or has been completed.

The "Encounter, Performed" participant references the primary participant.

Previous versions of QDM included an attribute principal diagnosis, defined as the condition that, after study, was determined to be the principal cause of the admission. QDM version 5.6 addresses that concept using the diagnosis rank=1.

Timing:

  • The relevantPeriod addresses:
    • startTime - The time the encounter began (admission time).
    • stopTime - The time the encounter ended (discharge time).
  • author dateTime references the time the action was recorded.
  • Refer to the eCQM expression to determine allowable timings to meet measure criteria.

Notes:

  • negation rationale indicates a one-time documentation of a reason an activity is not performed. Negation of QDM datatype-related actions for a reason always use the author dateTime attribute to reference timing and must not use relevantPeriod.
  • The locationPeriod is an attribute of the attribute facility location that addresses:
    • startTime - the time the patient arrived at the location. The time the encounter began (admission time).
    • stopTime - the time the patient departed from the location.
Value Set Description from VSAC
Clinical Focus: The purpose of this value set is to represent concepts for encounters or communications.
Data Element Scope: This value set may use a model element related to Encounter.
Inclusion Criteria: Includes concepts that represent an encounter in an office or care setting, as well as interactions that occur via virtual methods, such as telephone calls, emails, and letters.
Exclusion Criteria: No exclusions.

Constrained to codes in the Encounter, Performed: Patient Provider Interaction value set (2.16.840.1.113883.3.526.3.1012)

QDM Datatype and Definition

"Encounter, Performed"

Data elements that meet criteria using this datatype should document that the encounter indicated by the QDM category and its corresponding value set is in progress or has been completed.

The "Encounter, Performed" participant references the primary participant.

Previous versions of QDM included an attribute principal diagnosis, defined as the condition that, after study, was determined to be the principal cause of the admission. QDM version 5.6 addresses that concept using the diagnosis rank=1.

Timing:

  • The relevantPeriod addresses:
    • startTime - The time the encounter began (admission time).
    • stopTime - The time the encounter ended (discharge time).
  • author dateTime references the time the action was recorded.
  • Refer to the eCQM expression to determine allowable timings to meet measure criteria.

Notes:

  • negation rationale indicates a one-time documentation of a reason an activity is not performed. Negation of QDM datatype-related actions for a reason always use the author dateTime attribute to reference timing and must not use relevantPeriod.
  • The locationPeriod is an attribute of the attribute facility location that addresses:
    • startTime - the time the patient arrived at the location. The time the encounter began (admission time).
    • stopTime - the time the patient departed from the location.
Value Set Description from VSAC
Clinical Focus: The purpose of this value set is to represent concepts of medications of angiotensin-converting enzyme (ACE) inhibitor, angiotensin-receptor blocker (ARB), and angiotensin receptor-neprilysin inhibitor (ARNI) therapies.
Data Element Scope: This value set may use a model element related to Medication.
Inclusion Criteria: Includes concepts that represent a medication for angiotensin-converting enzyme (ACE) inhibitor, angiotensin-receptor blocker (ARB), and angiotensin receptor-neprilysin inhibitor (ARNI) therapies.s diuretic, ACEI plus calcium channel blocker, ARB plus calcium channel blocker, or ARB plus calcium channel blocker plus diuretic.
Exclusion Criteria: Excludes concepts that represent non-prescribable branded drugs, components or ingredients.

Constrained to codes in the Medication, Active: ACE Inhibitor or ARB or ARNI value set (2.16.840.1.113883.3.526.3.1139)

QDM Datatype and Definition

"Medication, Active"

Data elements that meet criteria using this datatype should document that the medication indicated by the QDM category and its corresponding value set is being taken by the patient. Keep in mind that when this datatype is used with timing relationships, the criterion is looking for a medication being taken for the time frame indicated by the timing relationships.

Timing:

  • relevant dateTime references the time the medication is active on the medication record if it was given or taken at a single point in time.
  • relevantPeriod references a start and stop time for an active medication on the medication record that is given or taken over a time interval:
  • The relevantPeriod addresses:
    • startTime = when the medication is first known to be used (generally the time of entry on the medication list).
    • stopTime = when the medication is no longer active.
Value Set Description from VSAC
Clinical Focus: The purpose of this value set is to represent concepts of medications of angiotensin-converting enzyme (ACE) inhibitor, angiotensin-receptor blocker (ARB), and angiotensin receptor-neprilysin inhibitor (ARNI) therapies.
Data Element Scope: This value set may use a model element related to Medication.
Inclusion Criteria: Includes concepts that represent a medication for angiotensin-converting enzyme (ACE) inhibitor, angiotensin-receptor blocker (ARB), and angiotensin receptor-neprilysin inhibitor (ARNI) therapies.s diuretic, ACEI plus calcium channel blocker, ARB plus calcium channel blocker, or ARB plus calcium channel blocker plus diuretic.
Exclusion Criteria: Excludes concepts that represent non-prescribable branded drugs, components or ingredients.

Constrained to codes in the Medication, Order: ACE Inhibitor or ARB or ARNI value set (2.16.840.1.113883.3.526.3.1139)

QDM Datatype and Definition

"Medication, Order"

Data elements that meet criteria using this datatype should document a request to a pharmacy to provide the medication indicated by the QDM category and its corresponding value set.

Timing:

  • relevantPeriod addresses the time referenced in the dosage instruction indicating when the medication administration should start and end.
  • author dateTime references the date and time the medication order (prescription) is authored.

Notes:

  • The medication order (prescription) is unlikely to indicate a relevantPeriod, the time period for which the ordered supply is to be administered/taken including all refills. Therefore, to determine the number of days covered by a single dispensing event, use the daysSupplied attribute and the relevant dateTime of the event to determine when the ordered medication will run out. If daysSupplied is not available, derive it from the supply (quantity of medication ordered) divided by the dosage (amount of medication to be taken at a single administration) times the frequency (number of units per time period – e.g., per day):
    daysSupplied = supply / (dosage x frequency)
    And multiply the daysSupplied per dispensing event multiplied by one plus the number of refills to determine the total daysSupplied ordered.
    daysSupplied x (1 + #refills)
    Starting with the relevant dateTime add the total daysSupplied (including refills) to determine when the ordered medication quantity will run out.
  • negation rationale indicates a one-time documentation of a reason an activity is not performed. Negation of QDM datatype-related actions for a reason always use the author dateTime attribute to reference timing and must not use relevantPeriod.

Refer to Special Cases in Section 5.7 for scenarios to consider in calculating cumulative medication duration.

Value Set Description from VSAC
Clinical Focus: The purpose of this value set is to represent concepts for medical reasons for not receiving a therapy or service.
Data Element Scope: This value set may use a model element related to Negation Rationale.
Inclusion Criteria: Includes concepts that describe a medical reason for not receiving a therapy or service.
Exclusion Criteria: No exclusions.

Constrained to codes in the Negation Rationale: Medical Reason value set (2.16.840.1.113883.3.526.3.1007)

QDM Attribute and Definition

negationRationale

Indicates the reason that an action was not performed. Only QDM datatypes that represent actions (e.g., performed, recommended, communication, order, dispensed) allow the negation rationale attribute. The intent is to indicate a justification that such action did not happen as expected. This attribute specifically does not address the presence or absence of information in a clinical record (e.g., documented absence of allergies versus lack of documentation about allergies). QDM assumes a world view that absence of evidence indicates information does not exist or an action did not happen. To express such lack of evidence, an eCQM author should use the CQL expression not exists with reference to the data element rather than the QDM data model. negation rationale in QDM signifies only a reason for such absence, i.e., the reason must be present to qualify for negation rationale. The syntax in the human readable HQMF is addressed in CQL examples and in the MAT User Guide. Prior versions of QDM used the syntax, Procedure, Performed not done. QDM versions starting with 5.3 use the syntax, Procedure, not Performed. Section A-5 provides examples for expressing negation rationale in CQL.

Note: negation rationale indicates a one-time documentation of a reason an activity is not performed. Negation of QDM datatype-related actions for a reason always use the author dateTime attribute to reference timing and must not use relevantPeriod.

For updated guidance and implementer feedback regarding use of the QDM negation rationale attribute see Section 6.6.

Value Set Description from VSAC
Clinical Focus: The purpose of this value set is to represent concepts for communication of a patient reason for declining angiotensin-converting enzyme (ACE) inhibitor or angiotensin ii receptor blocker (ARB) therapy.
Data Element Scope: This value set may use a model element related to Communication.
Inclusion Criteria: Includes concepts that represent a communication of declining angiotensin-converting enzyme (ACE) inhibitor or angiotensin ii receptor blocker (ARB) therapy.
Exclusion Criteria: No exclusions.

Constrained to codes in the Negation Rationale: Patient Reason For ACE Inhibitor Or ARB Decline value set (2.16.840.1.113883.3.526.3.1140)

QDM Attribute and Definition

negationRationale

Indicates the reason that an action was not performed. Only QDM datatypes that represent actions (e.g., performed, recommended, communication, order, dispensed) allow the negation rationale attribute. The intent is to indicate a justification that such action did not happen as expected. This attribute specifically does not address the presence or absence of information in a clinical record (e.g., documented absence of allergies versus lack of documentation about allergies). QDM assumes a world view that absence of evidence indicates information does not exist or an action did not happen. To express such lack of evidence, an eCQM author should use the CQL expression not exists with reference to the data element rather than the QDM data model. negation rationale in QDM signifies only a reason for such absence, i.e., the reason must be present to qualify for negation rationale. The syntax in the human readable HQMF is addressed in CQL examples and in the MAT User Guide. Prior versions of QDM used the syntax, Procedure, Performed not done. QDM versions starting with 5.3 use the syntax, Procedure, not Performed. Section A-5 provides examples for expressing negation rationale in CQL.

Note: negation rationale indicates a one-time documentation of a reason an activity is not performed. Negation of QDM datatype-related actions for a reason always use the author dateTime attribute to reference timing and must not use relevantPeriod.

For updated guidance and implementer feedback regarding use of the QDM negation rationale attribute see Section 6.6.

Value Set Description from VSAC
Clinical Focus: The purpose of this value set is to represent concepts for patient-specific reasons for not receiving a therapy or service.
Data Element Scope: This value set may use a model element related to Negation Rationale.
Inclusion Criteria: Includes concepts that represent a patient-specific reason for not receiving a therapy or service.
Exclusion Criteria: No exclusions.

Constrained to codes in the Negation Rationale: Patient Reason value set (2.16.840.1.113883.3.526.3.1008)

QDM Attribute and Definition

negationRationale

Indicates the reason that an action was not performed. Only QDM datatypes that represent actions (e.g., performed, recommended, communication, order, dispensed) allow the negation rationale attribute. The intent is to indicate a justification that such action did not happen as expected. This attribute specifically does not address the presence or absence of information in a clinical record (e.g., documented absence of allergies versus lack of documentation about allergies). QDM assumes a world view that absence of evidence indicates information does not exist or an action did not happen. To express such lack of evidence, an eCQM author should use the CQL expression not exists with reference to the data element rather than the QDM data model. negation rationale in QDM signifies only a reason for such absence, i.e., the reason must be present to qualify for negation rationale. The syntax in the human readable HQMF is addressed in CQL examples and in the MAT User Guide. Prior versions of QDM used the syntax, Procedure, Performed not done. QDM versions starting with 5.3 use the syntax, Procedure, not Performed. Section A-5 provides examples for expressing negation rationale in CQL.

Note: negation rationale indicates a one-time documentation of a reason an activity is not performed. Negation of QDM datatype-related actions for a reason always use the author dateTime attribute to reference timing and must not use relevantPeriod.

For updated guidance and implementer feedback regarding use of the QDM negation rationale attribute see Section 6.6.

Value Set Description from VSAC
Clinical Focus: n/a Data Element Scope: n/a Inclusion Criteria: n/a Exclusion Criteria: n/a

Constrained to codes in the Patient Characteristic, Ethnicity: Ethnicity value set (2.16.840.1.114222.4.11.837)

QDM Datatype and Definition

"Patient Characteristic, Ethnicity"

Data elements that meet criteria using this datatype should document that the patient has one or more of the ethnicities indicated by the QDM category and its corresponding value set.

Timing: Ethnicity does not have a specific timing. Measures using "Patient Characteristic, Ethnicity" should address the most recent entry in the clinical record.

Value Set Description from VSAC
Clinical Focus: Categories of types of health care payor entities as defined by the US Public Health Data Consortium SOP code system
Data Element Scope: @code in CCDA r2.1 template Planned Coverage [act: identifier urn:oid:2.16.840.1.113883.10.20.22.4.129 (open)] DYNAMIC
Inclusion Criteria: All codes in the code system
Exclusion Criteria: none

Constrained to codes in the Patient Characteristic, Payer: Payer value set (2.16.840.1.114222.4.11.3591)

QDM Datatype and Definition

"Patient Characteristic, Payer"

Data elements that meet criteria using this datatype should document that the patient has one or more of the payers indicated by the QDM category and its corresponding value set.

Timing:

The relevantPeriod addresses:

  • startTime – the first day of insurance coverage with the referenced payer.
  • stopTime – the last day of insurance coverage with the referenced payer.
Value Set Description from VSAC
Clinical Focus: n/a Data Element Scope: n/a Inclusion Criteria: n/a Exclusion Criteria: n/a

Constrained to codes in the Patient Characteristic, Race: Race value set (2.16.840.1.114222.4.11.836)

QDM Datatype and Definition

"Patient Characteristic, Race"

Data elements that meet criteria using this datatype should document the patient’s race.

Timing: Race does not have a specific timing. Measures using "Patient Characteristic, Race" should address the most recent entry in the clinical record.

Value Set Description from VSAC
Clinical Focus: Gender identity restricted to only Male and Female used in administrative situations requiring a restriction to these two categories.
Data Element Scope: Gender
Inclusion Criteria: Male and Female only.
Exclusion Criteria: Any gender identity that is not male or female.

Constrained to codes in the Patient Characteristic, Sex: ONC Administrative Sex value set (2.16.840.1.113762.1.4.1)

QDM Datatype and Definition

"Patient Characteristic, Sex"

Data elements that meet criteria using this datatype should document that the patient's sex matches the QDM category and its corresponding value set.

Timing: Birth (administrative) sex does not have a specific timing.

Value Set Description from VSAC
Clinical Focus: The purpose of this value set is to represent concepts of procedures for heart transplant.
Data Element Scope: This value set may use a model element related to Procedure.
Inclusion Criteria: Includes concepts that represent heart transplant.
Exclusion Criteria: No exclusions.

Constrained to codes in the Procedure, Performed: Heart Transplant value set (2.16.840.1.113762.1.4.1178.33)

QDM Datatype and Definition

"Procedure, Performed"

Data elements that meet criteria using this datatype should document the completion of the procedure indicated by the QDM category and its corresponding value set.

Timing:

  • relevant dateTime references the time the procedure is performed when the procedure occurs at a single point in time.
  • relevantPeriod references a start and stop time for a procedure that occurs over a time interval. relevantPeriod addresses:
    • startTime - The time the procedure begins.
    • stopTime - The time the procedure ends.
  • author dateTime references the time the action was recorded.
  • Refer to the eCQM expression to determine allowable timings to meet measure criterion.

Notes: 

  • Timing refers to a single instance of a procedure. If a measure seeks to evaluate multiple procedures over a period of time, the measure developer should use CQL logic to represent the query request.
  • The incision dateTime is a single point in time available from the Operating Room and/or Anesthesia Record.
  • negation rationale indicates a one-time documentation of a reason an activity is not performed. Negation of QDM datatype-related actions for a reason always use the author dateTime attribute to reference timing and must not use relevantPeriod.
  • See section 6.4 for guidance about differentiating between successful and unsuccessful procedures.
Value Set Description from VSAC
Clinical Focus: The purpose of this value set is to represent concepts of procedures for left ventricular assist device placement.
Data Element Scope: This value set may use a model element related to Procedure.
Inclusion Criteria: Includes concepts that represent procedures for left ventricular and biventricular device placement.
Exclusion Criteria: No exclusions.

Constrained to codes in the Procedure, Performed: Left Ventricular Assist Device Placement value set (2.16.840.1.113762.1.4.1178.61)

QDM Datatype and Definition

"Procedure, Performed"

Data elements that meet criteria using this datatype should document the completion of the procedure indicated by the QDM category and its corresponding value set.

Timing:

  • relevant dateTime references the time the procedure is performed when the procedure occurs at a single point in time.
  • relevantPeriod references a start and stop time for a procedure that occurs over a time interval. relevantPeriod addresses:
    • startTime - The time the procedure begins.
    • stopTime - The time the procedure ends.
  • author dateTime references the time the action was recorded.
  • Refer to the eCQM expression to determine allowable timings to meet measure criterion.

Notes: 

  • Timing refers to a single instance of a procedure. If a measure seeks to evaluate multiple procedures over a period of time, the measure developer should use CQL logic to represent the query request.
  • The incision dateTime is a single point in time available from the Operating Room and/or Anesthesia Record.
  • negation rationale indicates a one-time documentation of a reason an activity is not performed. Negation of QDM datatype-related actions for a reason always use the author dateTime attribute to reference timing and must not use relevantPeriod.
  • See section 6.4 for guidance about differentiating between successful and unsuccessful procedures.
Value Set Description from VSAC
Clinical Focus: The purpose of this value set is to represent concepts of severe and moderate levels of severity.
Data Element Scope: This value set may use a model element related to Severity.
Inclusion Criteria: Includes concepts that represent a Allergy/Intolerance, Adverse Event, Diagnosis, or Symptom with a severity of severe and moderate levels.
Exclusion Criteria: No exclusions.

Constrained to codes in the Severity: Moderate Or Severe value set (2.16.840.1.113883.3.526.3.1092)

QDM Attribute and Definition

severity

Indicates the intensity of the specified datatype (e.g., persistent, moderate, or severe).