download chevron-down chevron-right chevron-with-circle-down chevron-with-circle-up check circle-with-minus circle-with-plus export help-with-circle inbox link mail old-phone star-outlined star user v-card close close close Back to top
Top

Heart Failure (HF): Beta-Blocker Therapy for Left Ventricular Systolic Dysfunction (LVSD)

CMS Measure ID
CMS144v8
Version
8
NQF Number
0083e
Measure Description

Percentage of patients aged 18 years and older with a diagnosis of heart failure (HF) with a current or prior left ventricular ejection fraction (LVEF) < 40% who were prescribed beta-blocker therapy either within a 12-month period when seen in the outpatient setting OR at each hospital discharge

Initial Population

All patients aged 18 years and older with a diagnosis of heart failure

Denominator Statement

Equals Initial Population with a current or prior LVEF < 40%

Denominator Exclusions

None

Numerator Statement

Patients who were prescribed beta-blocker therapy either within a 12-month period when seen in the outpatient setting OR at each hospital discharge

Numerator Exclusions

Not Applicable

Denominator Exceptions

Documentation of medical reason(s) for not prescribing beta-blocker therapy (e.g., low blood pressure, fluid overload, asthma, patients recently treated with an intravenous positive inotropic agent, allergy, intolerance, other medical reasons).

Documentation of patient reason(s) for not prescribing beta-blocker therapy (e.g., patient declined, other patient reasons).

Documentation of system reason(s) for not prescribing beta-blocker therapy (e.g., other reasons attributable to the healthcare system).

Previous Version
Measure Scoring
Measure Type
Improvement Notation

Higher score indicates better quality

Guidance

A range value should satisfy the logic requirement for 'Ejection Fraction' as long as the ranged observation value clearly meets the less than 40% threshold noted in the denominator logic. A range that is inclusive of or greater than 40% would not meet the measure requirement.

To satisfy this measure, it must be reported for all heart failure patients at least once during the measurement period if seen in the outpatient setting. If the patient has an eligible inpatient discharge during the measurement period, as defined in the measure logic, it is expected to be reported at each hospital discharge.

Beta-blocker therapy:

-For patients with prior LVEF

The requirement of two or more visits is to establish that the eligible professional or eligible clinician has an existing relationship with the patient.

Quality ID
8

Specifications

Attachment Size
CMS144v8.html 104.05 KB
CMS144v8.zip 94.47 KB
CMS144v8-TRN.xlsx 22.01 KB

Release Notes

 

Header

  • Updated eCQM version number.

    Measure Section: eCQM Version number

    Source of Change: Measure Lead

  • Added 'e' to NQF number.

    Measure Section: NQF Number

    Source of Change: Standards Update

  • Updated copyright.

    Measure Section: Copyright

    Source of Change: Annual Update

  • Updated disclaimer.

    Measure Section: Disclaimer

    Source of Change: Measure Lead

  • Updated references to align with American Psychological Association (APA) style.

    Measure Section: Reference

    Source of Change: Measure Lead

  • Updated parenthetical citations to align with American Psychological Association (APA) style.

    Measure Section: Multiple Sections

    Source of Change: Measure Lead

 

Logic

  • In Population Criteria 2, replaced Quality Data Model (QDM) datatype 'Medication, Order' with 'Medication, Discharge' to improve alignment with measure intent in capturing medication at inpatient discharge.

    Measure Section: Numerator

    Source of Change: Measure Lead

  • In Population Criteria 2, replaced Quality Data Model (QDM) datatype 'Medication, Not Ordered' with 'Medication, Not Discharged' to improve alignment with measure intent.

    Measure Section: Denominator Exceptions

    Source of Change: Measure Lead

  • Replaced direct reference code LOINC (8867-4) with value set Heart Rate (2.16.840.1.113883.3.526.3.1176).

    Measure Section: Denominator Exceptions

    Source of Change: Measure Lead

  • Updated timing operator for cardiac pacer in situ diagnosis to 'overlaps after' to align with measure intent.

    Measure Section: Denominator Exceptions

    Source of Change: Measure Lead

  • Revised applicable definition titles to reflect modified Quality Data Model (QDM) 'Medication' datatype used within Population Criteria 2 Numerator and Denominator Exceptions.

    Measure Section: Definitions

    Source of Change: Measure Lead

  • Updated the names of Clinical Quality Language (CQL) definitions, functions, and/or aliases for clarification and to align with CQL Style Guide.

    Measure Section: Definitions and Functions

    Source of Change: Standards Update

  • Updated Clinical Quality Language (CQL) expression to conform with the HL7 Standard: Clinical Quality Language Specification, Release 1 STU 3 (CQL 1.3).

    Measure Section: Multiple Sections

    Source of Change: Standards Update

  • Updated definitions and functions in the Measure Authoring Tool (MAT) Global Common Functions Library to align with standards changes, Clinical Quality Language (CQL) Style Guide, and to include two new functions related to calculating hospital stays.

    Measure Section: Multiple Sections

    Source of Change: Standards Update

  • Updated version number of the Measure Authoring Tool (MAT) Global Common Functions Library (MATGlobalCommonFunctions-4.0.000).

    Measure Section: Multiple Sections

    Source of Change: Standards Update

 

Value Set

The VSAC is the source of truth for the value set content, please visit the VSAC for downloads of current value sets.

  • Value set Patient Provider Interaction (2.16.840.1.113883.3.526.3.1012): Deleted 6 SNOMED CT codes (12843005, 18170008, 19681004, 207195004, 4525004, 439708006).

    Measure Section: Terminology

    Source of Change: Annual Update

  • Value set Allergy to Beta Blocker Therapy (2.16.840.1.113883.3.526.3.1177): Deleted 1 SNOMED CT code (293971000).

    Measure Section: Terminology

    Source of Change: Annual Update

  • Value set Heart Failure (2.16.840.1.113883.3.526.3.376): Deleted 4 ICD-10-CM codes (I50.810, I50.811, I50.812, I50.813). Added 33 SNOMED CT codes and deleted 10 SNOMED CT codes (10335000, 128404006, 277639002, 359617009, 367363000, 426012001, 5053004, 60856006, 66989003, 80479009).

    Measure Section: Terminology

    Source of Change: Annual Update

  • Replaced direct reference code LOINC (8867-4) with value set Heart Rate (2.16.840.1.113883.3.526.3.1176).

    Measure Section: Terminology

    Source of Change: Measure Lead

  • Direct reference code for Birth date (LOINC Code (21112-8)) now displayed in Human Readable.

    Measure Section: Terminology

    Source of Change: Annual Update

  • ​Removed code system versions from direct reference codes. Please refer to Appendix A of the Electronic Clinical Quality Measure Logic and Implementation Guidance document for a list of code system versions used in the eCQM specifications for 2020 reporting/performance.

    Measure Section: Terminology

    Source of Change: Standards Update

  • Standardized purpose statement language in value sets across eCQMs. Value set purpose statements are visible in the Value Set Authority Center (VSAC) as well as the downloadable eCQM value set files.

    Measure Section: Terminology

    Source of Change: Measure Lead

Last Updated: Oct 10, 2019